Permit Information
Permit NumberELE18-02523
StatusFinaled
Name POWER PLUS INC
Site Address 9492 W EMERALD ST
Project NameSalvation Army
Customer Number 
ePlanReviewNo
Description
Alteration: Elec. for Salvation Army Building. (Bld18-00632)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/11/20199/11/20199/11/2019PPASS
DetailsTom Saunders
final Phone #: ###-#### Inspection requested via web by Debby Pierce...job complete...ok to final
Electrical Rough-In9/10/20199/10/20199/10/2019PPASS
DetailsJames Ady
exterior Phone #: ###-#### Inspection requested via web by Debby Pierce exterior lighting and receps including parking lot
Electrical Rough-In8/19/20198/20/20198/20/2019APASS
DetailsTom Saunders
roof Phone #: ###-#### Inspection requested via web by Debby Pierce....
3 mini split units need fuses down sized to 20A...check future inspection
Electrical Rough-In8/17/20198/19/20198/19/2019APASS
DetailsTom Saunders
2nd floor west side Phone #: ###-#### Inspection requested via web by Debby Pierce...
TCO 2nd floor and vestibule...marked on mini plan print
Electrical Rough-In8/12/20198/13/20198/13/2019APASS
DetailsTom Saunders
CHAPEL , ENTRY VESTIBULE AND LOBBY Phone #: ###-#### Inspection requested via web by Debby Pierce...
chapel only...ok to final for furniture
Electrical Rough-In8/8/20198/9/20198/9/2019APASS
DetailsJames Ady
2nd floor south east wing Phone #: ###-#### Inspection requested via web by Debby Pierce 314.20 Spark rings needed in Restroom tile. (Add-a-depths) Made a call to 363 to confirm requirment. . Area marked on print minus IT room ok to final.
Electrical Rough-In8/7/20198/7/20198/7/2019PPASS
DetailsRock A. Hudson
2nd floor north wing Phone #: ###-#### Inspection requested via web by Debby Pierce
Discussed disconnecting means for kitchen multi-pole appliances disconnecting means. As per 422.31(A)and(B) where circuit breaker is located with in sight of or is lockable in accordance with 110.25.
Level 2 north wing as noted on contractor print TCO ok for furniture.
Electrical Rough-In8/1/20198/2/20198/2/2019APASS
DetailsTom Saunders
1st. floor administrative area Phone #: ###-#### Inspection requested via web by Debby Pierce...

admin areas marked on contractor's plan copies ok for temp occupency to move furniture in
Electrical Rough-In7/16/20197/17/20197/17/2019APASS
DetailsTom Saunders
east lobby ceiling inspection Phone #: ###-#### Inspection requested via web by Debby Pierce...
grid ok to cover
Electrical Rough-In7/8/20197/8/20197/8/2019PPASS
DetailsTom Saunders
2nd. floor ceiling inspection Phone #: ###-#### Inspection requested via web by Debby Pierce...
2nd floor grid complete..ok to cover
Electrical Rough-In6/27/20196/28/20196/28/2019APASS
DetailsTom Saunders
ceiling inspection 1st. floor corridor and chapel. Phone #: ###-#### Inspection requested via web by Debby Pierce...ok to cover
Electrical Rough-In6/10/20196/11/20196/11/2019APASS
DetailsTom Saunders
1st. floor ceiling inspection Phone #: ###-#### Inspection requested via web by Debby Pierce...
ok to cover ceiling grid 1st floor excluding Chapel and main corridors
Electrical Rough-In4/4/20194/5/20194/5/2019APASS
DetailsTom Saunders
2nd. floor hard lid inspection Phone #: ###-#### Inspection requested via web by Debby Pierce...ok to cover
Electrical Rough-In3/21/20193/22/20193/22/2019PPASS
DetailsTom Saunders
2nd. floor south wall rough in. Phone #: ###-#### Inspection requested via web by Debby Pierce...
wall cover south walls 2nd floor ok
discussed piping above panels and sprinklers in electrical rm main switch gear
Electrical Rough-In3/14/20193/15/20193/15/2019APASS
DetailsTom Saunders
hard lid ceiling and soffits at chapel.
2nd floor north wing wall rough in. Phone #: ###-#### Inspection requested via web by Debby Pierce...
rough ok to cover...areas stated above and pony wall and comm area in chapel
Electrical Rough-In2/22/20192/22/20192/22/2019APASS
DetailsJames Ady
hard lid ceilings 1st floor Phone #: ###-#### Inspection requested via web by Debby Pierce All 1st floor Restroom hardlids only ok to cover
Electrical Rough-In2/13/20192/14/20192/14/2019APASS
DetailsTom Saunders
rough in inspection 1st. floor administration area Phone #: ###-#### Inspection requested via web by Debby Pierce...walls ok to cover
Electrical Rough-In2/5/20192/6/20192/6/2019PPASS
DetailsTom Saunders
rough in inspection pre-school area and chapel. Phone #: ###-#### Inspection requested via web by Debby Pierce...
wall cover for preschool classrooms downstairs
and perimeter walls in chapel...marked on plans
Conference11/30/201812/4/201812/4/2018APASS
DetailsTom Saunders
Steve Hook is contact at 208-71-1366. Phone #: ###-#### Inspection requested via web by Debby Pierce...
discussed one siding for specific areas
ok to one side 4ft down for ducting and piping as needed..discussed one siding of future areas and future conferences scheduled for those areas
Electrical Rough-In8/29/20188/29/20188/29/2018APASS
DetailsTom Saunders
underground....west side branch homeruns...ok to cover