Permit Information
Permit NumberELE19-03702
StatusFinaled
Name B & J ELECTRIC INC
Site Address 4332 N EYRIE WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: wire new home
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/5/20202/6/20202/6/2020APASS
DetailsMark Moncarr
lockbox 1319. Powder bath outlet is connected to GFCI in master bath and was tripped. Tile heat stat has been moved to allow access. Extension box on island. Phone #: ###-#### Inspection requested via web by Heath Thomas Ok final. Corrections made.
Final1/31/20202/3/20202/3/2020AFAIL
DetailsRock A. Hudson
lockbox 1319 Phone #: ###-#### Inspection requested via web by Heath Thomas
110.3- Poder bath receptacles not working.
Master bath floor heat thermostat too close to wall cannot reset GFCI in right side.
314.16- Receptacle installed for kitchen island counter top shall be of sufficient size for conductor allowance installed. 11.25 cubic inches installed in a 8 cubic inch box.
Electrical Rough-In12/27/201912/27/201912/27/2019PPASS
DetailsEric Story
Floor heat in master bathroom. Lockbox code on front door is 2520. Key is for dead bolt lock. Phone #: ###-#### Inspection requested via web by Heath Thomas
Master floor heat ok to cover
Rough-In Permanent Service10/17/201910/18/201910/18/2019APASS
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Heath Thomas Corrections made. Ok cover. p/s u/g n ok
Rough-In Permanent Service10/16/201910/17/201910/17/2019AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Heath Thomas
314.25- Recess can junction box covers shall be installed to totally enclose box as per manufacturers instructions. Master hall can, master bed can, kitchen can back junction box covers not flush with box.
* Complete dry sheeting ASAP! It is raining at time of inspection.