Permit NumberFIR19-00855
StatusFinaled
Name THORPE FIRE SPRINKLER SYSTEMS
Site Address 3425 N WINSOME RD
Project NameCHANEY RESIDENCE
Customer Number 
ePlanReviewYes
Description
TFSS TO INSTALL A NEW NFPA 13D FIRE SPRINKLER SYSTEM IN THIS NEW SINGLE FAMILY DWELLING.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection4/10/20204/10/20204/10/2020PPASS
DetailsJim Page
Plans have been updated, head is shown in washer/dryer room on level 2. Final fire sprinkler inspection is complete.

Ready any time. As built approved with added head on second floor. Sheetrock patched and finished where extra head was added. Phone #: ###-#### Inspection requested via web by Anthony Minichiello
INSP-Final Inspection3/24/20203/24/20203/24/2020PPART
DetailsJim Page
Previously noted item has been corrected, final fire sprinkler inspection is complete, plans to be submitted to show addition of fire sprinkler head in washer/dryer closet on level 2. A follow up inspection request will need to be requested after plans reflect added head, once plans match install then permit can be finaled.

Call James before heading out, thanks! Phone #: ###-#### Inspection requested via web by Anthony Minichiello
INSP-Final Inspection3/23/20203/23/20203/23/2020AFAIL
DetailsJim Page
Freeze protection/tenting no installed over new drop and piping to added head in washer/dryer closet, no cover until freeze protection is provided.

Call James before heading out, thanks! Phone #: ###-#### Inspection requested via web by Anthony Minichiello
INSP-Final Inspection3/18/20203/19/20203/19/2020AFAIL
DetailsJim Page
Room labeled closet off of level 2 bonus room has washer and dryer hook-ups added, per 2016 NFPA13D section 8.3.8 requires sprinkler protection in areas containing washer/dryers, a cover inspection will be required for tenting verification.

Call James before heading out, thanks! Phone #: ###-#### Inspection requested via web by Anthony Minichiello
INSP-Final Inspection3/16/20203/16/20203/16/2020PCANC
DetailsJim Page
Cancelled per conversation with point of contact, will be rescheduled for a later date.

Call James before heading out, thanks! Phone #: ###-#### Inspection requested via web by Anthony Minichiello
INSP-Sprinkler Rough-in12/26/201912/27/201912/27/2019PPASS
DetailsJim Page
Previously noted items have been corrected, rough to cover inspection for overhead fire sprinkler piping is complete, all tenting in place at time of inspection, cover is approved.

Overhead rough and tenting, call James before heading out - problem areas should be fixed by noon. Phone #: ###-#### Inspection requested via web by Anthony Minichiello
INSP-Sprinkler Rough-in12/23/201912/26/201912/26/2019ACANC
DetailsJim Page
Per conversation with point of contact, insualtion is still not correct, inspection request cancelled before inspection was started, inspection will be rescheduled for a later date.

Overhead rough and tenting, call James before heading out, thanks! Phone #: ###-#### Inspection requested via web by Anthony Minichiello
INSP-Sprinkler Rough-in12/23/201912/23/201912/23/2019PFAIL
DetailsJim Page
Could not locate city approved drawings at time of inspection. Tenting needs corrected in numerous places before cover can be approved.

Ready any time, call James before heading out. Overhead rough and tenting inspection. Phone #: ###-#### Inspection requested via web by Anthony Minichiello