Final | 8/28/2019 | 8/30/2019 | 8/30/2019 | A | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans-call for access code - final ok
|
Rough-in | 6/27/2019 | 6/28/2019 | 6/28/2019 | A | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans - R/I ok
|
Pressure Test | 6/21/2019 | 6/21/2019 | 6/21/2019 | A | PASS |
Chad Schwendiman
|
|
|
20lb gas pass
|
Rough-in | 6/20/2019 | 6/21/2019 | 6/21/2019 | A | FAIL |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans - Need to complete the crawl, need to insulate metal supply trunk in the crawl
|
Rough-in | 6/18/2019 | 6/19/2019 | 6/19/2019 | A | FAIL |
Jack Reynolds
|
|
|
It''s Open Phone #: ###-#### Inspection requested via web by Kim Evans - Stamped Man J onsite - 20lb gas pressure test fail - water heater b vent needs 1" clearances - range vent needs sealed - finished crawl space( duct work, dryer vent - line set needs supported in attic - line set and dryer vent needs nail plates - line set insulation needs rips fixed - supply trunk in crawl needs insulated - system needs fresh air installed
|