Final | 12/10/2019 | 12/11/2019 | 12/11/2019 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- final ok
|
Rough-in | 10/22/2019 | 10/22/2019 | 10/22/2019 | P | PASS |
Brian Scoles
|
|
|
we have approved manual on site now, please re-inspect Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok
|
Rough-in | 10/17/2019 | 10/18/2019 | 10/18/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need approved man j with right address onsite with right equipment- man j onsite for 10600 address- man j approved at this address has amana equipment
|
Rough-in | 10/17/2019 | 10/17/2019 | 10/17/2019 | P | FAIL |
Brian Scoles
|
|
|
corrections made, please re-inspect, please come AM Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- need approved man j onsite with right equipment brand and approved from city 2- insulation shield has gap off metal in attic insulation can come in contact with b vent for w/h
|
Rough-in | 10/15/2019 | 10/16/2019 | 10/16/2019 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- need ladder provided by contractor to access furnace/coil in attic 2- missing transfer in bedroom 2 3- need to seal dryer duct to termination box 4- need to fix/replace arma flex in wall attic bare copper showing 5- 6" outside air can not come from R/A can needs tied into R/A plenum at furnace- remove tap seal and insulate to r-6 over patch
left notice front window
|
Pressure Test | 10/15/2019 | 10/16/2019 | 10/16/2019 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
|