Permit Information
Permit NumberBLD19-02691
StatusIssued
Name WRIGHT BROTHERS THE BLDG CO EAGLE
Site Address 6916 W STATE ST
Project NameInstant Imprints T.I.
Customer Number 
ePlanReviewYes
Description
//PLAN MOD MINOR REVISION OF FLOOR PLAN// ***APPROVED REDUCTION OF WALL BETWEEN SHOWROOM & PRODUCTION BY 5'-0". QUICK TRANSACTION ASPECT WILL NOT BE COMPROMISED. MH 10/30/2019*** (INSTANT IMPRINTS) This building is fire sprinkled. Permit to remodel an existing 2,732 sq. ft. office / mercantile space. Vanilla demo only completed under BLD15-00945. Work to include: Construct interior non-load bearing walls, new interior doors, new exterior roll up door, new plumbing fixtures, new electrical panel, moved exterior roof ladder to adjacent wall, repair and replace roof walk pad as required. Structural engineering provided. Approval is contingent to adhering to the approved plans. Interior finishes shall be in compliance with Ch. 8 of the 2015 IBC. Any alterations or modifications to the buildings fire sprinkler or fire alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise fire department. MDH
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
CHANGE STATUS TO (ISS)  8/7/2020 DONE
Plan assigned to (M_H)7/30/2020 8/5/2020 DONE
DetailsMichael Hanson
08/05 plan mod
Routing - PLAN CHECK8/5/2020 8/5/2020 PASS
DetailsMichael Hanson
PLANS/APPL TAKEN TO FRONT DESK  8/5/2020 DONE
DetailsMichael Hanson
Permit Ready to Issue  8/5/2020 DONE
PLAN MOD
BLD-Aging Inspection7/30/20207/30/20207/31/2020 PEND
DetailsTony Young
Plan Modification Accepted  7/30/2020 DONE
relocated data closet and added 2' wing wall at mop closet
Telephone call  5/21/2020 DONE
email to GC, "You haven't passed your final yet. Please schedule for a final inspection to receive a final certificate of occ.
BLD-Final3/17/20203/18/20203/18/2020APART
DetailsDave Hannah
rear door access KEY Code 1208 Phone #: ###-#### Inspection requested via web by Josh Strasser ok for tco ok for perm co after fire gos perm
BLD-Final3/12/20203/13/20203/13/2020PNR
DetailsMike Jordan
Code lock box on the back door 1208 Phone #: ###-#### Inspection requested via web by Josh Strasser. Still needs plumbing final and fire alarm permit under review.
FIRE-Final Inspection3/12/20203/12/20203/12/2020APART
DetailsJim Page
Per conversation with Joe Bruce, Fire Section Supervisor, a 30 day TCO is authorized for life fire safety contingent upon the wall layout on plans reflect the wall change by the breakroom. One exit sign is in a different location as well as one exit sign missing, occupant load is under 49 according to permit details, exit signs are not required but if approved drawings show exit signage then exit signage will be required per architects design, a follow up inspection will be required after city approved plans are corrected.
FIRE-Final Inspection3/10/20203/11/20203/11/2020AFAIL
DetailsJim Page
Wall layout by breakroom area does not city approved drawings. Notated 2 areas that show exit sign/emergency lighting location but exit signs/emergency lighting are not in the city approved plan location. Provide exit discharge emergency illumination per note 12 on the building permit fire code review comments.

Back door lock box code is 1208 Phone #: ###-#### Inspection requested via web by Josh Strasser
BLD-Framing/Rough-in1/8/20201/9/20201/9/2020APART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Josh Strasser// walls ok after bracing as needed
Telephone call  11/26/2019 DONE
called ###-#### can not leave a message email tandrews@wbtbc.com and jconrad@wbtvc.com to requesting the sign permits to be return
Issue PAID IN FULL permit  11/21/2019 DONE
Print Occupancy Form  11/21/2019 DONE
Telephone call  11/21/2019 DONE
emailed permits to be sign to- jconrad@wbtbc.com and tandrews@wbtbc.com Eplan will need to be released
Telephone call  11/20/2019 DONE
Nichol Young confirmed new revised value is accurate
Telephone call  11/18/2019 DONE
Called Nicol who submitted a revised C of V that was $183,797. I asked him to double check and confirm with us the value.
Permit Ready to Issue  9/30/2019 DONE
all met:

NEED-
GC
Certificate of Value
Plan assigned to (M_H)8/2/2019 9/30/2019 DONE
DetailsMichael Hanson
1st review completed - 08/27 #520 L3 ePlan - Instant Imprints
Routing Off Site - STRUCTURAL9/27/2019 9/27/2019 PASS
DetailsMichael Hanson
Approved per ePlan review D. Haugland @ AHJ Engineering.
Route to Impact Fee Review8/29/20199/1/20198/29/2019 PASS
DetailsShannon Cade
Review requested for Commercial Permit
1st review completed  8/29/2019 FAIL
DetailsMichael Hanson
Routing Off Site - STRUCTURAL8/2/2019 8/29/2019 FAIL
DetailsMichael Hanson
See ePlan for corrections required per D. Haughland @ AHJ engineering.
Routing - Addressing8/2/2019 8/29/2019 PASS
DetailsDoug Chausow
Per ePlan approval.
Routing - PLAN CHECK8/2/2019 8/29/2019 FAIL
DetailsMichael Hanson
See changemarks in ePlan for corrections required.
Routing - FIRE8/2/20198/2/20198/28/2019 PASS
DetailsMark Scharfen
08/27-Instant Imprints 520 review complete. UPloaded rev_fire 08.28.2019l.pdf
Routing - PLUMBING8/2/2019 8/6/2019 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing - PLANNING8/2/2019 8/5/2019 PASS
DetailsNicolette Womack
Routing - MECHANICAL8/2/2019 8/5/2019 PASS
DetailsTroy James
Routing - Design Review8/2/2019 8/2/2019 PASS
DetailsKayCee Babb
Per sheets A1-1, A4-1, AS1-0, and M1-2, plans comply with CZC19-00197. Rear overhead door is for pedestrian use only. No merchandise or other obstructions are permitted within the pedestrian pathway to the rear of the property, excluding temporary use if accessible route around building is maintained. No outdoor stroage or overnight use of the pathway area is allowed.
Routing - PUBLIC WORKS8/2/2019 8/2/2019 PASS
DetailsAngela Hardy
Routing - Erosion and Sediment8/2/2019 8/2/2019 PASS
DetailsMichael Zawacki
No esc needed
Intake Approval  7/31/2019 PASS
Intake Approval  7/29/2019 FAIL
DetailsJulie Romig
need: 1. Form 310 uploaded with owner signature and engineer's stamp/signature. Also, all Form 310 pages with required special inspections checked.
2. Structural calcs/drawings that were emailed uploaded into ePlan.
3. Leave a 4"x2" blank space in the lower right hand corner, 3" off the right sheet edge, on all drawing sheets.
Application received  7/18/2019 DONE
Application submitted via PDS Online on Jul 18 2019 10:48PM