Final | 3/9/2020 | 3/9/2020 | 3/9/2020 | P | PASS |
Rock A. Hudson
|
|
|
Keegan Phone #: ###-#### Final ok
|
Final | 3/5/2020 | 3/6/2020 | 3/6/2020 | A | FAIL |
Rock A. Hudson
|
|
|
coffee bar & soup cooler ... call ahead // Keegan Phone #: ###-#### 300.15- All wiring to terminate in a box by approved means. Under west display added old circuit cut off about 18" out of conduit and left exposed.
|
Electrical Rough-In | 10/25/2019 | 10/25/2019 | 10/25/2019 | P | PASS |
Rock A. Hudson
|
|
|
Later if possible with a half hour notice ..... underground // Keegan Phone #: ###-#### Under slab for soup and hot/cold bars rough in ok cover
|
Final | 9/23/2019 | 9/23/2019 | 9/23/2019 | P | PART |
Rock A. Hudson
|
|
|
Permit to remain open for additional work still to complete. MC whip located at truss level shall terminate in a box as per 300.15. Open box located above coffee bar shall be covered as per 314.25. TCO of coffee bar only OK
|
Electrical Rough-In | 9/23/2019 | 9/23/2019 | 9/23/2019 | P | PASS |
Rock A. Hudson
|
|
|
Keegan Phone #: ###-#### Cloud rough in.
|
Electrical Rough-In | 9/12/2019 | 9/13/2019 | 9/13/2019 | A | PASS |
Rock A. Hudson
|
|
|
John Phone #: ###-#### Wall rough in ok cover
|
Electrical Rough-In | 9/6/2019 | 9/9/2019 | 9/9/2019 | A | PASS |
Rock A. Hudson
|
|
|
ground // John Phone #: ###-#### Low voltage portion of walker duct has been damaged by concrete saw. This section has been abandoned but will be sealed with flex seal to prevent concrete slurry from entering. Underslab of new coffee bar rough in ok cover
|
Issue PAID IN FULL permit | | | 8/13/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/13/2019 | | DONE |
|
|
|
This permit was created on the web by Stephanie Huston
|
First Notice | 3/9/2020 | 3/9/2020 | | | |
Rock A. Hudson
|
|
|
|