Final | 2/10/2020 | 2/10/2020 | 2/10/2020 | P | PASS |
Chad Schwendiman
|
|
|
Francisco is the contact. Air balance report has been emailed to you. Phone #: ###-#### Inspection requested via web by stan lillquist
|
Final | 2/6/2020 | 2/7/2020 | 2/6/2020 | A | CANC |
Chad Schwendiman
|
|
|
Francisco is the contact. Air Balance will be emailed to you prior to inspection. Phone #: ###-#### >> Inspection requested via web by stan lillquist Inspection cancelled from web by: stan lillquist
|
Rough-in | 2/3/2020 | 2/3/2020 | 2/3/2020 | P | FAIL |
Chad Schwendiman
|
|
|
Rough in roof work. Francisco is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist - Plumbing vents need to be 10' away from fresh air intake on MAU
|
Rough-in | 1/17/2020 | 1/17/2020 | 1/17/2020 | P | PASS |
Chad Schwendiman
|
|
|
rough in for ceiling cover. Francisco is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist
|
Rough-in | 1/8/2020 | 1/8/2020 | 1/8/2020 | P | PASS |
Chad Schwendiman
|
|
|
Shaft inspection on MUA duct. Francisco is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist
|
Rough-in | 11/26/2019 | 11/27/2019 | 11/27/2019 | A | PASS |
Chad Schwendiman
|
|
|
Restroom hardlids. Francisco is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist - Okay to cover hard lids in restrooms
|
Rough-in | 11/26/2019 | 11/27/2019 | 11/26/2019 | P | CANC |
Chad Schwendiman
|
|
|
Hardlid rough in bathrooms. Francisco is the contact Phone #: ###-#### >> Inspection requested via web by stan lillquist Inspection cancelled from web by: stan lillquist
|
Rough-in | 11/13/2019 | 11/13/2019 | 11/13/2019 | A | FAIL |
Chad Schwendiman
|
|
|
rough in hardlids in bathroom. I will be the contact. Phone #: ###-#### Inspection requested via web by stan lillquist - Need exhaust fans installed and ducted prior to sheet rocking the bathroom ceilings.
|
Issue PAID IN FULL permit | | | 11/8/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/8/2019 | | DONE |
|
|
|
This permit was created on the web by Scott Corriea
|
First Notice | 2/10/2020 | 2/10/2020 | | | |
Chad Schwendiman
|
|
|
|