Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberBLD19-02620
StatusTemporary Occupancy
Name PERRYMAN CONSTRUCTION MANAGEMENT IN
Site Address 7356 N LUCY ROSE LN
Project NameEaglehawk Fourplex - Bldg 4
Customer NumberBLD19-02617 TO BLD19-02622
ePlanReviewNo
Description
(EAGLEHAWK FOURPLEX MULTIFAMILY APARTMENTS – 7356 N. LUCY ROSE ST. – BUILDING 4) (6 BUILDING PERMITS UNDER BLD19-02617 IN EPLAN) //2-12-2020 PLAN MODIFICATION TO REPLACE MECHANICAL DESIGN WITH MANUAL S, J, ADJUSTMENTS TO MECHANICAL EQUIPMENT AND DUCTWORK. Jg.// Permit for the construction of a 4,852 sq. ft. 2-story four-unit apartment building. This building is one of six buildings within a multi-family development. Work to include general site work and the construction of the new building per the approved plans attached engineering and plan review report. Note: Special Inspections Required see form 310. This building is to be fully fire sprinklered with an NFPA 13-R system as required for residential occupancy. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection6/23/20206/24/20206/24/2020APASS
DetailsJim Page
Previously noted item has been corrected, final life fire safety inspection is complete.

Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Final6/22/20206/23/20206/23/2020PPASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson/ ok pending zoning and others
FIRE-Final Inspection6/22/20206/23/20206/23/2020PFAIL
DetailsJim Page
Correctly repair holes that were next to fire sprinkler heads in furnace closets.

Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Final6/17/20206/18/20206/23/2020PNR
DetailsTony Young
please call 30 minutes before inspection Phone #: ###-#### Inspection requested via web by bill gullickson
FIRE-Final Inspection6/17/20206/18/20206/18/2020PCANC
DetailsJim Page
Duplicate inspection request, this request is cancelled.

please call 30 minutes before inspection Phone #: ###-#### Inspection requested via web by bill gullickson
FIRE-Final Inspection6/17/20206/18/20206/18/2020PCANC
DetailsJim Page
Duplicate inspection request, this request is cancelled.

please call 30 minutes before inspection Phone #: ###-#### Inspection requested via web by bill gullickson
FIRE-Final Inspection6/17/20206/18/20206/18/2020PFAIL
DetailsJim Page
Riser room is not 1 hour rated as required under BMC 7-01-51. Provide apartment numbers instead of apartment letters as specified under the Building Permit Fire Code Review Comments section 12A. Sprinkler escutcheon needs to cover entire sprinkler hole penetration, furnace rooms in apartments labeled A, C and D at time of inspection had large gaps between sheetrock and edge of escutcheon.

Hard wire riser room heaters instead of plug in as discussed.
please call 30 minutes before inspection Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Footing6/2/20206/2/20206/2/2020PNR
DetailsTell Riley
Gazebo inspection - Lynda Phone #: ###-####//plans show Gazebo is not part of the permit//let onsite contact know//no plans for gazebo onsite--cannot find permit associated with gazebo//will re-schedule when permit is obtained//
BLD-Wall Bracing4/1/20204/2/20204/2/2020APASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson// exterior was ok to cover
BLD-Energy code compliance3/9/20203/10/20203/10/2020PPASS
DetailsTony Young
Insulation inspection. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Framing/Rough-in3/5/20203/6/20203/6/2020PPASS
DetailsTony Young
Framing inspection. Please call Nic a half hour before inspection. Cheers, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Wall Bracing2/14/20202/18/20202/18/2020ACANC
DetailsTony Young
Ed Phone #: ###-#### Inspection cancelled from web by: Nic Van Diepen
BLD-Framing/Rough-in1/24/20201/24/20201/24/2020PPART
DetailsTony Young
Exterior osb shear inspection. Please call Nic a half hour before inspection. Cheers, Phone #: ###-#### Inspection requested via web by Nic Van Diepen// exterior ok to cover
BLD-Wall cover1/8/20201/9/20201/9/2020APASS
DetailsTony Young
Party wall truss GWB shear inspection. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Concrete12/13/201912/13/201912/13/2019APASS
DetailsTony Young
Building interior slab on grade. Concrete at 9:30am. Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Energy code compliance11/22/201911/22/201911/25/2019PPASS
DetailsTony Young
Foundation rigid Insulation inspection. Thanks! Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Footing11/12/201911/13/201911/13/2019PPASS
DetailsTony Young
Pat Phone #: ###-####