Permit Information
Permit NumberBLD19-04915
StatusIssued
Name SCOTT HEDRICK CONSTRUCTION
Site Address 3201 W AIRPORT WAY
Project NameAirport - Boarding Bridge C8A
Customer Number 
ePlanReviewYes
Description
(BOISE AIRPORT - BOARDING BRIDGE C8A) ***PLAN MOD UPDATING THE STRUCTURAL ONLY DUE TO ACTUAL ONSITE CONDITIONS*** The fire sprinkler system is used to substitute for 1-hr fire-resistance-rated construction of the concourse building. Certificate of completion to be issued upon final inspection approval. Permit to construct a fixed 100 foot long elevated passenger boarding bridge to connect Concourse C to the fixed end of a passenger boarding bridge at Gate C8A (which has the capacity telescope and rotate about the fixed end). Work to include: interior ramp, exterior footings and installation of a pre-manufactured passenger boarding bridge, electrical work, and plumbing work. Approval is contingent on adhering to the approved plans, notations, local codes and ordinanaces. Interior finishes shall be in compliance with Ch. 8 of the 2015 IBC. This building is fully fire sprinkled. Any alterations or modifications to the buildings fire sprinkler or fire alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise fire department. **MDH**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Framing/Rough-in8/6/20208/7/20208/7/2020PPASS
DetailsJim Storey
Requesting PM inspection for framing. Please call 30 minutes prior to meet at gate 50 to be escorted. Thanks!

Frank Phone #: ###-#### Inspection requested via web by Frank Loucks exterior wall ok
BLD-Concrete7/29/20207/30/20207/30/2020APART
DetailsJim Storey
Requesting inspection for a concrete/rebar ramp at Gate C8A for a 11:00AM concrete pour. Call 30 minutes prior to be escorted to job site
MTI will be on site to witness the epoxy of smooth dowels and rebar.
Thanks! Phone #: ###-#### Inspection requested via web by Frank Loucks // si on site pending report.
BLD-Foundation7/8/20207/8/20207/8/2020PPASS
DetailsJim Storey
Requesting to call 30 min prior to meet at gate 50 to be escorted in SIDA badge area. Thanks! Phone #: ###-#### Inspection requested via web by Frank Loucks pending si report
BLD-Foundation7/1/20207/1/20207/1/2020PPEND
DetailsDave Hannah
Please call before coming so I can meet you at gate 50 to be escorted into the job site. If you don''t know where gat 50 is, call me so I can you give directions Thanks! Phone #: ###-#### Inspection requested via web by Frank Loucks ok after spec inspection sign off