Permit Information
Permit NumberBLD20-00308
StatusIssued
Name GRAVES CREEK LLC
Site Address 1666 S ENTERTAINMENT AVE
Project NameCosta Vida T.I.
Customer NumberBLD20-00725
ePlanReviewYes
Description
(COSTA VIDA) (TWO PERMITS IN EPLAN UNDER BLD20-00308) There are two permits under this ePlan one for Costa Vida and one for the Vanilla T.I. (BLD20-00725). No occupancy is allowed under this permit. Future tenants shall apply for occupancy prior to occupying either space. This building is fire sprinkled for area increase. Permit to remodel an existing 7,840 sqft restaurant A-2 building. The remodel will divide the existing building into two tenant spaces this permit is for 3,705 sqft West side space and BLD20-00725 for vanilla T.I. 2,915 sqft East side space the remodel will eliminate 1,220 sqft from the originally constructed total area. Work to include: extensive demo work including removal of exterior windows, exterior doors, roof, interior non-bearing partition walls, millwork, commercial kitchen, mechanical work, plumbing work, and electrical work. New work to include: exterior windows, exterior doors, roof, interior non-bearing partition walls, doors, millwork, walk-in cooler, commercial kitchen, demising wall, mechanical work, electrical work, and plumbing work. Existing bathrooms to remain and shared by both tenant spaces. Interior finishes shall be in compliance with Ch. 8 of the 2015 IBC. Any alterations or modifications to the buildings fire sprinkler or fire alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise fire department. **MDH**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/4/20208/5/20208/5/2020APART
DetailsMike Jordan
Kyle *screened* Phone #: ###-####. OK for temp occ. Needs to revise scope of work or submit aditional plans for occupancy. Provide final letter from special inspection agency and RFI from engineer for east footing.
BLD-Final8/3/20208/4/20208/4/2020ANR
DetailsMike Jordan
Kyle */Screened*/ Phone #: ###-####
FIRE-Final Inspection8/3/20208/4/20208/4/2020APART
DetailsTroy Cobbley
A temp for life safety is being given until the project related fire alarm permit is finaled.

Phone #: ###-####
BLD-Final7/31/20208/3/20208/3/2020PNR
DetailsMike Jordan
screened // Kyle Phone #: ###-####. Needs fire/life/safety and zoning finals.
FIRE-Final Inspection7/31/20208/3/20208/3/2020AFAIL
DetailsTroy Cobbley
Need the project related firer alarm and hood suppresion permits finaled. Need all small documents, need address, need the exit signs and emergency lights repaired, need verification the room/walls at the cooler/fire riser room is ok to delete.

screened // Kyle Phone #: ###-####
BLD-Ceiling Grid Inspection7/28/20207/29/20207/29/2020PPASS
DetailsMike Jordan
SCREENED // Kyle Phone #: ###-####
BLD-Ceiling Grid Inspection7/27/20207/28/20207/28/2020ANR
DetailsMike Jordan
screened // Kyle Phone #: ###-####
BLD-Framing/Rough-in7/20/20207/20/20207/20/2020PPASS
DetailsMike Jordan
support framing for overbuilds at parapets.
BLD-Framing/Rough-in7/17/20207/20/20207/20/2020APASS
DetailsMike Jordan
screened // Andrew Phone #: ###-####. Insualtion above freezer ok.
BLD-Framing/Rough-in7/14/20207/15/20207/15/2020APASS
DetailsMike Jordan
Andrew *screened** Phone #: ###-####
BLD-Framing/Rough-in7/1/20207/2/20207/2/2020PFAIL
DetailsMike Jordan
Kyle Phone #: ###-####. Needs to provide updated strucutural details for steel studs in lieu of LVL studs for exterior furouts. Need special inspection reports for concrete and epoxy to date. Also needs to provide fire conferance on exterior furouts. Called Kyle at above number and left message. do not cover furouts at this time.
BLD-Footing6/15/20206/16/20206/16/2020APASS
DetailsMike Jordan
screened // Andrew Phone #: ###-####. . remainder of footings for bumpouts.
BLD-Footing6/10/20206/11/20206/11/2020APART
DetailsMike Jordan
Screened- Andrew Phone #: ###-####. Footing for freezer slab and architectual bump outs ok. Need enginner of records approval for new footing at storefront.