Permit Information
Permit NumberBLD19-02849
StatusFinaled
Name DG CONST LLC
Site Address 2249 N LONGVIEW PL
Project NameNELSON RESIDENCE
Customer Number 
ePlanReviewNo
Description
**HILLSIDE** **W.U.I. HILLSIDE ZONE A CLASS "A" ROOF AND NON-COMBUSTIBLE EXTERIOR SIDING REQUIRED** **310 SPECIAL INSPECTIONS** **PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 2972 sq. ft., two story (first story 2246 sq. ft., basement 726 sq. ft.) single family dwelling with 3 bedrooms, 2.5 bathrooms, approximately 954 sq. ft. of covered patio/porch and a 1163 sq. ft. attached garage per the approved plans and any notations. R-1A zoning and setbacks per planning. JJN ***SPRINKLERS ARE REQUIRED***LGMA letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.

An erosion and sediment control site preparation inspection is required for this site. The site preparation inspection takes place after all required erosion and sediment control best management practices have been installed and BEFORE any earthwork takes place. Call 208-608-7070 to schedule an inspection.

Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/28/20204/30/20204/30/2020APART
DetailsJim Storey
screened // Dennis Phone #: ###-#### e mail tony w blower door test .
DOC - Permit Finaled4/30/20204/30/20204/30/2020PPASS
DetailsJim Storey
PubWorks Occupancy Approval4/28/20204/28/20204/28/2020 DONE
DetailsMelissa Jannusch
A letter from the applicant’s design professional indicating that the final grading and drainage (including roof drainage connection to the subdivision system and stabilization) is acceptable has been received by Public Works. Final occupancy may be approved by the building department. Melissa Jannusch ###-####.
BLD-Other2/10/20202/11/20202/11/2020APASS
DetailsTony Young
Dennis Phone #: ###-####// soffits,, work in progress,, ok
BLD-Wall Bracing2/7/20202/10/20202/10/2020PPART
DetailsTony Young
Dennis Phone #: ###-####,, interior work in progress,, ok
BLD-Energy code compliance1/31/20202/3/20202/3/2020PPASS
DetailsTony Young
Dennis Phone #: ###-####
BLD-Framing/Rough-in1/29/20201/30/20201/31/2020PPASS
DetailsDave Hannah
Dennis Phone #: ###-####
BLD-Wall Bracing1/2/20201/2/20201/2/2020PPASS
DetailsDave Hannah
lance Phone #: ###-####
BLD-Conference12/23/201912/23/201912/23/2019PPEND
DetailsTony Young
verify rear setbacks,, measures 15 foot from wood frame to existing fence sent photos to Tom in Code enforcement
BLD-Footing11/12/201911/12/201911/12/2019PPASS
DetailsTony Young
rebar/viber barrier- Ryan Phone #: ###-####. interior footings in basement slab ok,, vapor barrior in place
BLD-Foundation10/22/201910/23/201910/23/2019APASS
DetailsBrandon Shaw
Work in progres...
PubWorks Subgrade Approval10/21/201910/21/201910/21/2019 DONE
DetailsMelissa Jannusch

A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Melissa Jannusch ###-####.

BLD-Footing10/17/201910/18/201910/18/2019APART
DetailsTell Riley
Ryan Phone #: ###-####//garage and crawl footings//setbacks per plans//footing per plan//
BLD-Footing9/26/20199/27/20199/27/2019APASS
DetailsTony Young
Brain Phone #: ###-####,, last section of footing/ wall ok
BLD-Foundation9/20/20199/23/20199/23/2019APART
DetailsTell Riley
Ryan-wall Phone #: ###-####//basement only//will need to call in for remainder of foundation//
BLD-Footing9/12/20199/13/20199/13/2019APART
DetailsJim Storey
Ryan Phone #: ###-#### rebar/ft west end ok
Plan Reviewer's activity  9/13/2019 DONE
DetailsJenny Nelson
Talked to Dennis Geis, engineer shortening height of a few foundation walls to conform with land on site, not changing structure at all. Said to talk to inspector. Already did foundation inspection, if inspector thinks needs plan mod then we can do one.
PubWorks Subgrade Approval9/11/20199/11/20199/11/2019 DONE
DetailsMelissa Jannusch
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Melissa Jannusch ###-####.

Issue PAID IN FULL permit  8/26/2019  
OVERRIDE  8/23/2019  
Plan assigned to (J_N)7/29/20197/29/20198/23/2019 DONE
DetailsJenny Nelson
08/15 sfd L2 Paper, 8/13 skipped planning and mech during routing, waiting for those reviews to be finished
Routing PW Grading-Hillside8/13/2019 8/23/2019 PASS
DetailsMelissa Jannusch
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at ###-#### with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at ###-####.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.

An erosion and sediment control site preparation inspection is required for this site. The site preparation inspection takes place after all required erosion and sediment control best management practices have been installed and BEFORE any earthwork takes place. Call ###-#### to schedule an inspection.

Routing - PUBLIC WORKS8/13/2019 8/23/2019 PASS
DetailsAngela Hardy
Case Summary (BLD)  8/23/2019 DONE
DetailsJenny Nelson
PLANS/APPL TAKEN TO FRONT DESK  8/23/2019 DONE
DetailsJenny Nelson
Permit Ready to Issue  8/23/2019 DONE
ALL MET- Need
RP
Applicant needs to sign application and checklist and uploaded it
Inspection Record Card- Bld  8/23/2019 DONE
Routing - MECHANICAL8/13/2019 8/15/2019 PASS
DetailsTroy James
Routing - FIRE8/13/20198/13/20198/13/2019 PASS
DetailsLee G Meredith
Sprinklers are required.
1st review completed  8/13/2019 DONE
DetailsJenny Nelson
Routing - PLAN CHECK8/13/2019 8/13/2019 PASS
DetailsJenny Nelson
Routing - MECHANICAL  8/13/2019 FAIL
Emailed corrections to designer
Routing - PLANNING  8/13/2019 PASS
Approved per CFH19-00043
Routing - FIRE8/9/2019 8/12/2019 FAIL
DetailsLee G Meredith
08/09-2249 N Longview 404 Paper RESIDENTIAL. LGM

Inadequate fire flow at hydrant. Resubmittal with sprinklers required
Plan resubmittals received  8/9/2019 DONE
Three copies of each grading plans C1 and C1.1 stamped and taken to plan reivewer
Routing - Erosion and Sediment8/7/2019 8/9/2019 PASS
DetailsAndy J. Long
ESC plan approved. Certified RP listed. Site preparation inspection is required.
Routing PW Grading-Hillside7/30/2019 8/6/2019 FAIL
DetailsMelissa Jannusch
see e-mail to applicant
Route to Impact Fee Review7/29/20198/1/20197/30/2019 PASS
DetailsShannon Cade
Initial residential review of new SFD permits requested for now.
Routing - Addressing  7/30/2019 PASS
Plans ACCEPTED BY PLAN CHECK  7/29/2019 DONE
Recd Pcfee & Taken To Pln CK  7/29/2019 DONE
Intake Approval  7/29/2019 PASS
Application received 7/29/2019   
Routing - PUBLIC WORKS7/29/2019   FAIL
SEE HILLSIDE FOR FAIL