Final | 2/14/2019 | 2/14/2019 | 2/14/2019 | P | PASS |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by Eric Brown Corrections made. Ok final.
|
Final | 2/12/2019 | 2/12/2019 | 2/12/2019 | P | FAIL |
Mark Moncarr
|
|
|
Thank you Phone #: ###-#### Inspection requested via web by Eric Brown All electrical work associated with home is good. A/C disconnects for mini split system needs corrections made by heating company. In disc to right, neutral wires need identified as hot conductors. NM cable in left disc cannot be used in outdoor damp or wet locations. Bushing also need for wires exiting wall into disc. Western Heating and Air were the installers.
|
Rough-In Permanent Service | 10/5/2018 | 10/5/2018 | 10/5/2018 | P | PASS |
Mark Moncarr
|
|
|
Thank you and have a great day. Phone #: ###-#### Inspection requested via web by Eric Brown p/s u/g n ok
|
Issue PAID IN FULL permit | | | 10/2/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/2/2018 | | DONE |
|
|
|
This permit was created on the web by Bonnie Page
|