Final | 7/1/2018 | 7/2/2018 | 7/2/2018 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- final ok
|
Final | 6/29/2018 | 6/29/2018 | 6/29/2018 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- intake air for furnace not installed per manufactures recommendations for snow load/ grade above ground
|
Final | 6/28/2018 | 6/29/2018 | 6/29/2018 | A | FAIL |
Brian Scoles
|
|
|
LATE AM PLZ Phone #: ###-#### Inspection requested via web by Oleg Chervak- corrections still not made
|
Final | 6/22/2018 | 6/22/2018 | 6/22/2018 | P | FAIL |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak - Need approved supports on PVC flue, and gas piping, need combustion air for mechanical room
|
Final | 6/21/2018 | 6/21/2018 | 6/21/2018 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- no airbalance report onsite- upstairs bedroom has carpet over register- need combustion air for furnace in downstairs room
|
Final | 6/21/2018 | 6/21/2018 | 6/21/2018 | A | CANC |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Todd Campbell- schedule for afernoon
|
Rough-in | 3/1/2018 | 3/2/2018 | 3/2/2018 | A | PASS |
Ben Livingston
|
|
|
LATE AM PLZ Phone #: ###-#### Inspection requested via web by Oleg Chervak
|
Rough-in | 3/1/2018 | 3/1/2018 | 3/1/2018 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need approved manual J onsite
|
Rough-in | 2/27/2018 | 2/28/2018 | 2/28/2018 | A | FAIL |
Brian Scoles
|
|
|
Inspection requested via web by Oleg Chervak- no manual J onsite- need to submit manual J for approval- cant do inspection without one- why is there 2 mechanical permits for this house ??
|
Pressure Test | 2/27/2018 | 2/28/2018 | 2/28/2018 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass- 5lb flue pass
|
Issue PAID IN FULL permit | | | 2/27/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/27/2018 | | DONE |
|
|
|
This permit was created on the web by Oleg Chervak
|