Information based on query as of Friday, May 17, 2024.
Permit Information
Permit NumberBLD16-04502
StatusFinaled
Name PERRYMAN CONSTRUCTION MANAGEMENT IN
Site Address 12640 W IRVING ST
Project NameThe Cottages at White Clouds
Customer NumberBLD16-04501
ePlanReviewYes
Description
(2 PERMITS IN EPLAN UNDER PERMIT BLD16-04502) **Special inspection required, see for #310** Permit for the construction of a new 1,007 sq. ft., two story (first story 425 sq. ft., second story 582 sq. ft.) Townhouse with 2 bedrooms, 2.5 bathrooms, and a 460 sq. ft. attached garage per the approved plans, plan review report and any notations. R-1C zoning and setbacks per planning. **BJM**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/8/201810/8/201810/8/2018PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Sam Brown
DOC - Permit Finaled10/8/201810/8/201810/8/2018PPASS
DetailsMike Jordan
BLD-Blower Door Test Results10/8/201810/8/201810/8/2018PDONE
DetailsMike Jordan
6.0 ACH@ 50pa
BLD-Energy code compliance7/20/20187/20/20187/20/2018APASS
DetailsMike Jordan
BLD-Framing/Rough-in7/20/20187/20/20187/20/2018APASS
DetailsMike Jordan
BLD-Energy code compliance7/16/20187/16/20187/16/2018PNR
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Sam Brown
BLD-Framing/Rough-in7/16/20187/16/20187/16/2018PFAIL
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Sam Brown. Needs to complete install of SDS screws and nail of h2.5
BLD-Energy code compliance7/16/20187/16/20187/16/2018ACANC
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Sam Brown Inspection cancelled from web by: Sam Brown
BLD-Framing/Rough-in7/16/20187/16/20187/16/2018ACANC
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Sam Brown Inspection cancelled from web by: Sam Brown
BLD-Framing/Rough-in7/11/20187/11/20187/11/2018AFAIL
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Sam Brown. Provide stud shoes on 2x6 wall in garage were notched for gas pipe. 2hr. fire wall does not extend to exterior wall in garage at attic space. Fireblock fur down in closet downstairs. finsish installing SDs screws on 6x6 columns for elevated patio. provide aditional stud under CO3 two ply girder upstairs and nail off h2.5. orrection notice issued. Ik to insulate.
BLD-Wall Bracing4/3/20184/3/20184/3/2018PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Sam Brown
BLD-Footing12/5/201712/5/201712/5/2017PPASS
DetailsMike Jordan
Rebar - Shane Phone #: ###-####. Interior thickend footings.
BLD-Foundation10/23/201710/23/201710/23/2017PPASS
DetailsMike Jordan
Sam Phone #: ###-####. Rigid insualtion on stemwall under slab on grade.
BLD-Foundation10/18/201710/18/201710/18/2017PPASS
DetailsMike Jordan
Sam Phone #: ###-####
BLD-Footing10/17/201710/17/201710/17/2017PPASS
DetailsMike Jordan
Manny Phone #: ###-####