Permit NumberBLD17-04133
StatusFinaled
Name ESI
Site Address 3266 E BARBER VALLEY DR
Project NameVeranda at Barber Station
Customer NumberBLD18-00230/FND BLD17-03587
ePlanReviewYes
Description
(VERANDA AT BARBER STATION Building A) (2 PERMITS IN EPLAN UNDER BLD17-04133) **PROJECT MANAGEMENT - Angie Brosious ""PLAN MODIFICATION 2 FOR MECHANICAL ALTERATIONS AND INSTALLATION OF A LIFT STATION 11/27/18"" ""PLAN MODIFICATION FOR MECHANICAL DUCTING, INSTALLATION OF A LIFT STATION AT THE GREASE INTERCEPTOR"" Permit for the construction of a 36,087 sq. ft. 45 room memory care center (foundation and site under BLD17-03587) with work to include the construction of a new wood framed building with all associated interior and exterior finsihes per the approved plans. This building is fully fire sprinklered for area increas and occupancy type. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/25/20192/25/20192/25/2019PPASS
DetailsBrandon Shaw
Scott Phone #: ###-####
DOC - Permit Finaled2/25/20192/25/20192/25/2019PPASS
DetailsBrandon Shaw
FIRE-Final Inspection2/22/20192/25/20192/25/2019APASS
DetailsJim Page
Final life fire safety inspection complete.

Scott Phone #: ###-####
BLD-Final1/31/20191/31/20191/31/2019PPART
DetailsBrandon Shaw
Temp C of O has been OK'd...
FIRE-Final Inspection1/30/20191/30/20191/30/2019APART
DetailsJim Page
TCO for fire life safety approved per conversation with Ron Johnson for 30 days for vendor/employee training only. Once fire alarm permit is finaled then life fire safety can be signed off as finaled.

Schedule to come at the same time as the Fire Alarm inspection. Thanks Phone #: ###-#### Inspection requested via web by JT Turner
FIRE-Final Inspection1/28/20191/29/20191/29/2019ACANC
DetailsTroy Cobbley
Need the project related FIR permits scheduled and finaled prior to a life safety inspection.

Phone #: ###-#### Inspection requested via web by JT Turner
FIRE-Final Inspection1/28/20191/28/20191/28/2019PFAIL
DetailsJim Page
FIR permits for fire alarm, fire alarm communicator and hood suppression system needs to be completed and finaled before life fire safety inspection can be completed.

Phone #: ###-#### Inspection requested via web by JT Turner
BLD-Wall cover11/14/201811/15/201811/15/2018APART
DetailsBrandon Shaw
Need Engineer fix for two broken trusses at BLDG B main entry...
OK to isulate...
BLD-Energy code compliance10/5/201810/5/201810/5/2018PPART
DetailsBrandon Shaw
Air Seal inspection for area A.
BLD-Energy code compliance9/5/20189/5/20189/5/2018PPART
DetailsBrandon Shaw
Air seal BLDG- C to common area
BLD-Framing/Rough-in8/30/20188/30/20188/30/2018PPART
DetailsBrandon Shaw
Area C shower stall drywall and tape
BLD-Framing/Rough-in8/28/20188/29/20188/29/2018APART
DetailsBrandon Shaw
Corrections SAT...
BLD-Framing/Rough-in8/27/20188/27/20188/27/2018PPART
DetailsBrandon Shaw
BLDG D- OK to cover exterior and one side of individual units