Permit Information
Permit NumberBLD18-02751
StatusFinaled
Name LAYTON CONSTRUCTION
Site Address 6663 S EISENMAN RD Unit: 140
Project NameD-Bat Academy Boise
Customer Number 
ePlanReviewYes
Description
(D-BAT ACADEMY BOISE – BUILDING C – NORTH END OF BUILDING) (SUITE 140) (DRH17-00215) The fire sprinkler system is used for building area increase and for fire area. To construct improvements within an existing 20,318 square foot shell tenant space located in the North end of Building C for an assembly occupancy to be used as a baseball and softball pitching and hitting training facility. This shell tenant space was demised under permit BLD17-02817 when the 51,402 square foot building shell was constructed. This tenant space is required to be separated from the rest of the building by a 1-hr fire barrier wall to function as an occupancy separation. Work is to include interior steel stud walls, a gypsum board and steel stud ceiling above the office and retail sales area, two toilet rooms accessible to the disabled, vinyl coated chain-link fencing to define an egress corridor, soft wall netting for pitching and batting tunnels, new storefront glazing to replace an overhead door, suspended acoustical ceilings, suspended gypsum board ceilings, millwork, and finishes. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/10/201812/11/201812/11/2018PPASS
DetailsMike Jordan
Tim Phone #: ###-####. ok for perm occ.
FIRE-Final Inspection12/10/201812/11/201812/11/2018APASS
DetailsJim Page
Previously noted items have been corrected, fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers are in place with current inspection tags. Final life fire safety inspection for area of work complete.

Tim Phone #: ###-####
BLD-Final12/6/201812/7/201812/7/2018PNR
DetailsJim Storey
Tim Phone #: ###-####
FIRE-Final Inspection12/6/201812/7/201812/7/2018AFAIL
DetailsTroy Cobbley
Relocate the fire extinguisher as discussed, repair the exit sign and provide inspection/final for the fan shutdown.

Tim Phone #: ###-####
FIRE-Final Inspection12/7/201812/7/201812/7/2018PCANC
DetailsJim Page
Tim Phone #: ###-####
BLD-Ceiling Grid Inspection11/20/201811/21/201811/21/2018APASS
DetailsJim Storey
Tim Phone #: ###-####
BLD-Ceiling Grid Inspection10/31/201811/1/201811/1/2018APASS
DetailsJim Storey
Tim Phone #: ###-####
BLD-Framing/Rough-in10/16/201810/16/201810/16/2018PPASS
DetailsJim Storey
Tim Phone #: ###-####
BLD-Framing/Rough-in10/5/201810/8/201810/8/2018PPASS
DetailsJim Storey
dave Phone #: ###-#### meet with engineer of record// ok to cover/ ceilling