Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberBLD19-03364
StatusFinaled
Name SIMPLICTY HOMES LLC
Site Address 2007 S SURREY RD
Project NameJENKINS RESIDENCE
Customer Number 
ePlanReviewYes
Description
**PASSES USING UA TRADE OFF** Permit for the construction of a new 2438 sq. ft., two story (first story 1980 sq. ft., second story 458 sq. ft.) single family dwelling with 5 bedrooms, 3 bathrooms, approximately 130 sq. ft. of covered patio/porch and a 482 sq. ft. attached garage per the approved plans and any notations. R-1A zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/6/20204/7/20204/7/2020APASS
DetailsMike Jordan
Screened- Sam Phone #: ###-####
BLD-Blower Door Test Results4/7/20204/7/20204/7/2020ADONE
DetailsMike Jordan
4.6
DOC - Permit Finaled4/7/20204/7/20204/7/2020PPASS
DetailsMike Jordan
BLD-Energy code compliance1/21/20201/21/20201/21/2020PPASS
DetailsMike Jordan
Sam Phone #: ###-####
BLD-Framing/Rough-in1/15/20201/16/20201/16/2020APASS
DetailsMike Jordan
Sam Phone #: ###-####. All framing correction have been made. Ok to insulate.
BLD-Framing/Rough-in1/13/20201/13/20201/13/2020PFAIL
DetailsMike Jordan
Sam Phone #: ###-####. Complete lateral bracing on F04 and A02 trusses. Fireblock either side of archway in hall and concelled space at ceiling next to archway. Strap double top plate break at beam seat from beam in garage. Install the 4 simpson screws into each stud for the 2x12 ledger connection. Anchor bolts required for the interior bearing wall in garage. Did the inteior thickend footing get placed with slab? Correction notice posted. Ok to insulate.
BLD-Wall Bracing12/11/201912/12/201912/12/2019APASS
DetailsMike Jordan
Sam Phone #: ###-####
BLD-Foundation11/21/201911/21/201911/21/2019PCANC
DetailsMike Jordan
pour at 1:30 // SAm Phone #: ###-####
BLD-Footing11/21/201911/21/201911/21/2019PPASS
DetailsMike Jordan
pour at 1:30 // SAm Phone #: ###-####
BLD-Footing11/20/201911/21/201911/21/2019AFAIL
DetailsMike Jordan
Sam Phone #: ###-####. Column pad footings not the min. 10 inches deep per the approved plans. Also noted that ground, rebar and form work below the min. 34 degress required for concrete placement.