Final | 6/13/2020 | 6/15/2020 | 6/15/2020 | P | PASS |
Rock A. Hudson
|
|
|
NOT ON SITE. BACK DOOR OPEN. CALL WITH QUESTIONS. Phone #: ###-#### Inspection requested via web by Garrett Collins No card posted. Final ok
|
Electrical Rough-In | 10/29/2019 | 10/29/2019 | 10/29/2019 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Garrett Collins Discussed area to right of ranges may have counter top added beyond where receptacle outlets have been roughed in. At final receptacle outlets shall be installed to comply with 210.52(C), would be OK to install at end of cabinet due to pocket door. Unit 6 rough in ok cover
|
Electrical Rough-In | 10/24/2019 | 10/25/2019 | 10/25/2019 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Garrett Collins Units 2 and 4 rough in ok cover
|
Electrical Rough-In | 10/8/2019 | 10/9/2019 | 10/9/2019 | P | PASS |
Rock A. Hudson
|
|
|
Units one and five Phone #: ###-#### Inspection requested via web by Garrett Collins Units noted rough in ok cover
|
Electrical Rough-In | 10/4/2019 | 10/7/2019 | 10/7/2019 | P | PASS |
Rock A. Hudson
|
|
|
On site Phone #: ###-#### Inspection requested via web by Garrett Collins BLD states only remodelling kitchens and bathrooms in each unit with smokes added. Wall cover not removed in most of units. Basement lids and unit 3 only rough in ok cover
|
Electrical Rough-In | 7/11/2019 | 7/11/2019 | 7/11/2019 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Garrett Collins BLD19-02329 is still under review, unable to do inspections until it has been issued. 210.52- Several areas do not comply with receptacle layout of living spaces. Smoke detectors not roughed in. BLD will determine complete scope of work.
|
Permanent Service | 4/11/2019 | 4/12/2019 | 4/12/2019 | P | PASS |
Rock A. Hudson
|
|
|
Ok to energize. Neil on site Phone #: ###-#### Inspection requested via web by Garrett Collins 65k rated main, will verify available fault current in future as per 110.9 and 110.24. p/s o/h rec ok
|
Conference | 4/8/2019 | 4/8/2019 | 4/8/2019 | P | DONE |
Rock A. Hudson
|
|
|
Service mast Phone #: ###-#### Inspection requested via web by Garrett Collins Discussed overhead service entrance clearance from windows. New service mast will be located between windows and from attachment point should clear windows by well over the 3' needed. Will install 2 ground rods and will include metal underground water pipe in future if needed. New panels will be installed in each unit with new house panel, new codes only apply to new work being performed.
|