Final | 2/14/2019 | 2/14/2019 | 2/14/2019 | A | PASS |
Brian Scoles
|
|
|
correction made-
|
Final | 1/30/2019 | 1/31/2019 | 1/31/2019 | A | FAIL |
Brian Scoles
|
|
|
Client will be at location at 9am. Please call prior to arrival at ###-#### Thank you Inspection requested via web by Andrea Grigsby- furnace a/c coil co ok- flue from furnace needs grade has sag
|
Final | 1/3/2019 | 1/7/2019 | 1/7/2019 | A | FAIL |
Brian Scoles
|
|
|
Please call Rich 30 min prior if no call customer will not be there. If you call ahead he will make sure someone is there Phone #: ###-#### Inspection requested via web by Andrea Grigsby- bubble wrap insulation needs 3/4" gap to maintain R-6 value- b vent needs 1" clearance to combustibles at roof- flex b vent from furnace needs grade from furnace to b vent wye
|
Final | 11/29/2018 | 12/4/2018 | 12/4/2018 | A | NH |
Brian Scoles
|
|
|
Please call client at ###-#### prior to arrival Thank you Phone #: ###-#### Inspection requested via web by Andrea Grigsby- called number listed twice no answer- went by no one their- no access
|
Pressure Test | 10/8/2018 | 10/9/2018 | 10/9/2018 | A | PASS |
Brian Scoles
|
|
|
Please call customer (Julie Robinson) 30 min prior to arrival at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- 20lb gas pass
|