ESC-Conference | 5/19/2020 | 5/20/2020 | 5/28/2020 | P | PEND |
Andy J. Long
|
|
|
|
ESC-Conference | 4/29/2020 | 5/13/2020 | 5/19/2020 | P | PEND |
Andy J. Long
|
|
|
Not vegetated. No muddy runoff observed, but a lot of runoff from this building and the Crane Creek parking lot
|
ESC-Conference | 4/29/2020 | 5/13/2020 | 5/12/2020 | A | DONE |
Andy J. Long
|
|
|
No sediment leaving site. Hill doesn't seem to be vegetating. Follow up scheduled. BLD permit is still open
note - entry is from 4/29. new inspection on schedule
|
ESC-Conference | 4/9/2020 | 4/28/2020 | 4/29/2020 | P | PEND |
Andy J. Long
|
|
|
|
ESC-Conference | 3/24/2020 | 4/9/2020 | 4/9/2020 | P | PEND |
Andy J. Long
|
|
|
No new activity or erosion. No vegetation establishing yet, still need to work on roof access grading.
|
ESC-Conference | 3/24/2020 | 3/24/2020 | 3/24/2020 | P | CANC |
Andy J. Long
|
|
|
|
ESC-Conference | 3/4/2020 | 3/18/2020 | 3/24/2020 | P | PEND |
Andy J. Long
|
|
|
Corrective actions have been intiated at site: - Perimeter sediment control wattle installed along Curling as requested. - Placed wattle to slow down runoff on the roof access road. - No loose dirt on sidewalk or parking area - Owner Jon states hillside has been seeded as requested.
Notified Jon that the wattle placement and clean up was good, but the wattles need to be trenched into the ground so water does not flow under them.
Will check vegetation establishment and wattle trenching in 2 weeks.
|
ESC-Conference | 2/27/2020 | 2/28/2020 | 3/4/2020 | A | PEND |
Andy J. Long
|
|
|
Met with building owner Jon ###-####. Disturbance occurred digging out side of the shelter to install new fire & sprinkler lines.
Review stormwater and erosion controls that should be implemented.
1. Berm road to prevent flow of water down the roof access to the slope 2. Rake in seeding into the bare/disturbed areas 3. Install perimeter control wattles around disturbed slope 4. Install slope interupting/water check wattles on the roof access road.
Will follow up in 2 weeks.
|
Application received | | | 2/27/2020 | | |
|
|
|
|
Issue Misc Permit............ | | | 2/27/2020 | | DONE |
|
|
|
|
ESC-Conference | 5/28/2020 | 6/2/2020 | | P | |
Andy J. Long
|
|
|
|