Information based on query as of Thursday, May 16, 2024.
Permit Information
Permit NumberBLD19-02583
StatusIssued
Name ESI
Site Address 8821 W USTICK RD
Project NameCole Community Church Office
Customer Number 
ePlanReviewYes
Description
(COLE COMMUNITY CHURCH ADMINSTRATIVE OFFICES – HOUSE TO OFFICE CONVERSION) (CUP19-00040) (12-17-19 PLAN MODIFICATION TO CHANGE THE REQUIRED ACCESSIBLE ROUTE FOR THE DISABLED FROM THE EAST BUILDING ENTRANCE TO THE NORTH BUILDING ENTRANCE. THE EXISTING EAST BUILDING ENTRANCE WILL BE INFILLED WITH A NEW EXTERIOR WALL.) This building does not have a fire sprinkler system. To convert an existing 2,564 square foot single-family dwelling to administrate offices to be used by the adjacent church. This floor area includes the 1,926 square foot office area, the 535 square foot garage, and the 86 square foot breezeway. All residential uses in this building are required to be abandoned. The 535 square foot garage is now classified as an S-2 occupancy parking garage. The 828 square foot basement is approved only for mechanical equipment. This building is not approved for classroom use. It is approved for office use and for limited meeting room use associated with the office use. Work is to include interior nonbearing walls, two single-user toilet rooms accessible to the disabled, interior doors, exterior doors, and finishes. Cooking operations that create grease laden vapors are not allowed. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. Provide an analysis and design by an Engineer licensed in the State of Idaho as a deferred submittal before any bearing walls are removed. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection6/4/20206/4/20206/5/2020 PEND
DetailsTell Riley
needs to turn in signature card
BLD-Aging Inspection6/3/20206/3/20206/4/2020 PEND
DetailsTell Riley
BLD-Final1/17/20201/21/20201/21/2020APASS
DetailsTell Riley
brandon Phone #: ###-####//corrections made//sreen door removed at accessible entry//accesible entry route signs installed//
CHANGE STATUS TO (ISS)  12/18/2019 DONE
Plan assigned to (CJW)12/11/201912/11/201912/17/2019 PASS
DetailsCarl Westfall
PLAN MOD (permits desk)
Routing - PLAN CHECK12/16/2019 12/17/2019 PASS
DetailsCarl Westfall
1st plan mod intake review approved and IBC plan review approved
PLANS/APPL TAKEN TO FRONT DESK  12/17/2019 DONE
Permit Ready to Issue  12/17/2019 DONE
plan mod approved
Route to Impact Fee Review12/11/201912/14/201912/12/2019 PASS
DetailsTravis P Black
Review requested for Commercial Permit
Plan Reviewer's activity  12/12/2019 FAIL
The plan mod plan intake review was not approved. The revised sheet is required to be stamped and signed by the Architect. The accessible parking space is required to be located on the shortest accessible route to the accessible entrance.
Plan Modification Accepted  12/11/2019 DONE
Amy Lindgren from Cushing Terril submitting a request to begin a plan modification workflow. Accessible route has been modified from the originally submitted plans. Sheet G001-COVER AND CODE PLAN
BLD-Final12/5/201912/6/201912/6/2019AFAIL
DetailsTell Riley
Call before coming- Brandon Phone #: ###-####//CN issued for olan mod for accessible route and parking, directional signage for non accessible doors, toilet flush lever on wrong side, safety glazing in accordance with the plan review report//
FIRE-Final Inspection12/4/201912/5/201912/5/2019APASS
DetailsTroy Cobbley
Life safety passed. Provide sticker at main exit prior to the building inspection. Storage has been removed from basement, seating has been removed from the first floor. At time of inspection building appears to meet scope of work use.

Brandon Phone #: ###-####
FIRE-Final Inspection11/18/201911/19/201911/19/2019AFAIL
DetailsTroy Cobbley
Provide plan modifications showing the actual use of the Open Office area and the basement. There is currently 42 chairs set up in the open office area for use as music/performance and the basement is being used as storage. Also provide single action hardware on all doors as discussed. Provide and mount the fire extinguishers upstairs and downstairs as discussed. Brandon- Phone #: ###-####
BLD-Final11/15/201911/18/201911/18/2019ACANC
DetailsTell Riley
Brandon Phone #: ###-####//needs fire life safety inspection completed prior to final//left message with contact//will need to re-schedule final//
Zoning Approval10/7/201910/7/201910/7/2019 DONE
DetailsEthan Mansfield
BLD-Framing/Rough-in9/17/20199/18/20199/18/2019APASS
DetailsTell Riley
Terry Phone #: ###-####//trades passed//framing ok per plans///
BLD-Framing/Rough-in9/16/20199/17/20199/17/2019PPART
DetailsTell Riley
Terry Phone #: ###-####//partial for office area//all other areas with mechanical need inspections//
Issue PAID IN FULL permit  8/13/2019 DONE
Print Occupancy Form  8/13/2019 DONE
Plan assigned to (CJW)7/19/20198/15/20198/8/2019 PASS
DetailsCarl Westfall
(1st done) 08/08/19 (L-3 - 15 days) (eplan - 15 sheets) Cole Community Church (waiting for fire)
PLANS/APPL TAKEN TO FRONT DESK  8/8/2019 DONE
1st review completed  8/8/2019 DONE
Permit Ready to Issue  8/8/2019 DONE
MET THOMASCARLSON@ESICONSTRUCTION.COM
Need
ACHD-met
GC Form
Revised Value
Routing - FIRE7/19/20197/19/20198/7/2019 PASS
DetailsMark Scharfen
08.07.2019-uploaded rev_fire 08.07.2019.pdf. Completed fire review.
Routing - PLAN CHECK7/19/2019 8/2/2019 PASS
DetailsCarl Westfall
Routing - MECHANICAL7/19/2019 7/24/2019 PASS
DetailsTroy James
Routing - PLUMBING7/19/2019 7/22/2019 PASS
DetailsDaryl Spivey
Per plan and ISPC
Routing - PLANNING7/19/2019 7/22/2019 PASS
DetailsEthan Mansfield
Routing - Addressing7/19/2019 7/22/2019 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS7/19/2019 7/22/2019 PASS
DetailsMorgan Webb
Intake Approval  7/19/2019 PASS
Intake Approval  7/17/2019 FAIL
DetailsJoe Bruce
Provide the following items to complete the prescreen process:
1) Plan sheets (A101, P001) do not have the required space reserved for City approval stamps as specified in the Electronic Plans Submittal Standards. Revise sheets with a blank 4” x 2” space located 3” off the right sheet edge to allow for the title block. Verify ALL plan sheets have the required space for city approval stamp.
2) Engineering Structural Calculations are missing a stamp by the structural engineer
Application received  7/12/2019 DONE
Application submitted via PDS Online on Jul 12 2019 10:34AM