Information based on query as of Thursday, May 9, 2024.
Permit Information
Permit NumberBLD18-02909
StatusIssued
Name JANE THARPE
Site Address 2417 W BANK DR Unit: 101
Project NameGem Center for the Arts
Customer Number 
ePlanReviewYes
Description
(GEM CENTER FOR THE ARTS - SUITE #101) Permit is to remodel an existing 2,484 sq. ft. space on the main floor for assembly art exhibit use. Approval is contingent upon adhering to the approved plans on file and plan review report. Work to include: minor interior finish repairs and replacement such as trim work, carpet, paint and suspended acoustic ceiling tiles, interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection1/17/20201/17/20201/17/2020 PASS
DetailsJim Storey
BLD-Aging Inspection9/5/20199/5/20199/5/2019 PASS
DetailsJim Storey
Jane Phone #: ###-#### final ok/ lost card
BLD-Final4/23/20194/24/20194/24/2019PPASS
DetailsJim Storey
Jane Phone #: ###-#### final ok/ lost card
FIRE-Final Inspection4/1/20194/1/20194/1/2019PPASS
DetailsJim Page
Previously noted items have been corrected, no fire sprinkler modifications, fire alarm inspection is complete, fire extinguisher is placed and will be tagged with a current inspection tag. Final life fire safety inspection for area of work complete.

Jane Phone #: ###-####
BLD-Final3/25/20193/26/20193/26/2019PNR
DetailsJim Storey
Jane Phone #: ###-####
BLD-Final3/25/20193/26/20193/26/2019PNR
DetailsJim Page
301 added call before going out .
FIRE-Conference2/11/20192/11/20192/11/2019ADONE
DetailsJim Page
Fire conference complete.
FIRE-Final Inspection2/8/20192/11/20192/11/2019ACANC
DetailsJim Page
Inspection request was for a conference, this request is cancelled.

Jane Phone #: ###-####
BLD-Final2/8/20192/11/20192/11/2019ANR
DetailsJim Storey
Jane 200/75 ceilling and wall coverings// 32 min exit path/ panice hardware double doors/ unlock sign at single.
FIRE-Final Inspection1/31/20192/1/20192/1/2019PFAIL
DetailsJim Page
Need to have tenant verify that the finishes in art exhibit rooms comply with chapter 7 of the International Fire Code. Fire sprinkler modifications are required for tenant space. Fire alarm modifications are required for tenant space. Any modifications to fire alarm and fire sprinkler system requires a permit. Provide fire extinguisher for proper coverage.

Jane Phone #: ###-####