Information based on query as of Saturday, May 4, 2024.
Permit Information
Permit NumberFIR19-00672
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 4101 N CARTWRIGHT RD
Project NameHolman Residence
Customer Number 
ePlanReviewYes
Description
Shilo will install a new fire sprinkler system into the new Holman Residence per NFPA 13D, 2016, and the City of Boise
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection12/6/201912/9/201912/9/2019APASS
DetailsTroy Cobbley
**PASS** Hydro papers and paperwork showing factory painted escutcheons uploaded to tidemark*MAS** Gabe is the contact. Thanks for all you do! Phone #: ###-#### >> Inspection requested via web by Stan Beus
DOC - Permit Finaled  12/9/2019 DONE
DetailsMark Stumbaugh
INSP-Final Inspection12/5/201912/6/201912/6/2019ACANC
DetailsJim Page
Point of contact not available when inspection could be completed, inspection request will need to be rescheduled, this request is cancelled.

Gabe is the contact. Thanks for all you do! Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Sprinkler Rough-in/Hydro12/4/201912/5/201912/5/2019PPASS
DetailsTroy Cobbley
Overhead hydro witnessed with no pressure loss.

Gabe Garduno is the contact. Thanks for all you do! Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Sprinkler Rough-in9/25/20199/25/20199/25/2019PPASS
DetailsJim Page
Plan mods have been accepted, all tenting is in place, cover is approved for overhead fire sprinkler piping.

Gabe Garduno is the contact. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Sprinkler Rough-in9/17/20199/18/20199/18/2019APART
DetailsJim Page
Previously noted items have been corrected, rough in inspection for overhead fire sprinkler piping is complete, plan mod still needs to be submitted as of this entry, cover is not approved until plan mod has been reviewed and accepted.

Gabe Garduno is the contact. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Conference9/13/20199/16/20199/16/2019AFAIL
DetailsJim Page
** Failed. Plan Mod needed for piping changes. Head at entryway needs moved for proper coverage. Piping on 2nd floor in unheated concealed space needs rerouted out of concealed space to allow for proper freeze protection. GC to build wall in storage area under stair so head is no more than 10' away. Discussed insulation options, and requirements with GC.*MAS**
Gabe Garduno is the contact for this consultation. Thank you for your help. Have a great day. Phone #: ###-#### >> Inspection requested via web by Stan Beus