**PRESCRIPTIVE ENERGY REQUIREMENTS** (TWO PERMITS FILED UNDER BLD19-02007) Permit for the construction of a new 1513 sq. ft., 2 story (first story 674 sq. ft., second story 839 sq. ft.) Townhouse with 3 bedrooms, 2.5 bathrooms, 56 sq. ft. covered patio/porch and a 400 sq. ft. attached garage per the approved plans and any notations. C-1D zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/28/20203/2/20203/2/2020APASS
DetailsMike Jordan
JIm Phone #: ###-####
DOC - Permit Finaled3/2/20203/2/20203/2/2020PPASS
DetailsMike Jordan
BLD-Blower Door Test Results3/2/20203/2/20203/2/2020ADONE
DetailsMike Jordan
4.7
BLD-Final2/24/20202/25/20202/25/2020AFAIL
DetailsMike Jordan
Carl Phone #: ###-####. Complete fire cauliking in garage and provide blower door test results.
BLD-Framing/Rough-in11/6/201911/7/201911/7/2019APASS
DetailsMike Jordan
sheet rock framing // Jim Phone #: ###-####
Release Hold on Job  11/6/2019 DONE
Removed parcel hold because they paid the reinspection fee per Michael Z
BLD-Framing/Rough-in10/24/201910/25/201910/25/2019APASS
DetailsMike Jordan
jim Phone #: ###-####
BLD-Energy code compliance10/25/201910/25/201910/25/2019APASS
DetailsMike Jordan
jim Phone #: ###-####
BLD-Wall cover10/24/201910/24/201910/24/2019PNR
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Carl Funk
BLD-Framing/Rough-in10/24/201910/24/201910/24/2019PNR
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Carl Funk
BLD-Framing/Rough-in10/21/201910/21/201910/21/2019PFAIL
DetailsMike Jordan
Complete lateral bracing on A3 trusses. Complete fireblocking on furdowns. Nail off all simpson hangars and provide fixes for trusses at entry way. Ok to insulate.
BLD-Framing/Rough-in10/18/201910/21/201910/21/2019ACANC
DetailsMike Jordan
JIM Phone #: ###-####. Moved to pm inspection.
BLD-Framing/Rough-in10/15/201910/15/201910/15/2019PFAIL
DetailsMike Jordan
Jim Phone #: ###-####
BLD-Conference9/30/20199/30/20199/30/2019PDONE
DetailsMike Jordan
Jim Phone #: ###-####
BLD-Wall Bracing9/30/20199/30/20199/30/2019PPASS
DetailsMike Jordan
Jim Phone #: ###-####
BLD-Wall Bracing9/27/20199/27/20199/27/2019AFAIL
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by Carl Funk//need to address nailing and blocking at portal frames//sthds in wrong locations//windows added in shear location at front entry//2 hr wall contruction does not match plans//
BLD-Wall Bracing9/17/20199/18/20199/18/2019AFAIL
DetailsMike Jordan
Carl Phone #: ###-####. Needs to provide a full set of approved plans. Notes say there should be a total of eight pages of construction docs. Omly seven are provided. Wall bracing plans are incomplete, missing schedules. Also noted that 2hr. wall is not continous or constructed per plans.
BLD-Foundation8/16/20198/16/20198/16/2019PPASS
DetailsMike Jordan
stem wall // Willie Phone #: ###-####
BLD-Footing8/9/20198/12/20198/12/2019APASS
DetailsMike Jordan
Sergio Phone #: ###-####
BLD-Footing8/8/20198/9/20198/9/2019AFAIL
DetailsMike Jordan
Sergio Phone #: ###-####. Approved plans shows duplex 1hr. wall seoeration, per scope of work, townhouses are being constructed, which require a 2hr. seperation. Plans to be resubmitted.
BLD-Footing8/8/20198/8/20198/8/2019PFAIL
DetailsMike Jordan
surgeo Phone #: ###-####. No city approved plans on site.
Issue PAID IN FULL permit  7/30/2019 DONE
Inspection Record Card- Bld  7/30/2019 DONE
Telephone call  7/26/2019 DONE
GC will be here next week to submit 302 and sign for permits
OVERRIDE  7/24/2019  
Plan assigned to (J_N)7/10/20197/10/20197/24/2019 DONE
DetailsJenny Nelson
2nd review, waiting for planning. 1st complete 7/12, wall bracing, floor joist main floor, ul or ga
Routing - PLANNING7/22/2019 7/24/2019 PASS
DetailsBrent Moore
PLANS/APPL TAKEN TO FRONT DESK  7/24/2019 DONE
DetailsJenny Nelson
Permit Ready to Issue  7/24/2019 DONE
ALL MET -NEED RP
DO NOT ISSUE WITHOUT BLD19-02010
7-26-19 owner changed GC- needs to provide New GC
Routing - PLAN CHECK7/22/2019 7/22/2019 PASS
DetailsJenny Nelson
1st review completed  7/12/2019 DONE
DetailsJenny Nelson
Routing - PLAN CHECK7/10/2019 7/12/2019 FAIL
DetailsJenny Nelson
Route to Impact Fee Review7/10/20197/13/20197/11/2019 PASS
DetailsShannon Cade
Initial residential review of new SFD permits requested for now.
Routing - MECHANICAL7/10/2019 7/10/2019 PASS
DetailsTroy James
Routing - PLANNING7/10/2019 7/10/2019 FAIL
DetailsBrent Moore
Need to show distance from 2nd floor to west property line. 15' setback required.
Routing - Addressing7/10/2019 7/10/2019 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS7/10/2019 7/10/2019 PASS
DetailsAngela Hardy
Plans ACCEPTED BY PLAN TECH  7/10/2019 DONE
Intake Approval  7/10/2019 PASS
Recd Pcfee & Taken To Pln CK  7/10/2019 DONE
Meeting  7/9/2019 DONE
emailed brandon that 02010 needs to be paid too
Intake Approval  6/27/2019 FAIL
1. Stair section detail showing dimensions of treads, risers, headroom, handrails, & guard requirements.
2. elevation height to top of roof
3. energy compliance- REScheck
4. Label furnace and air conditioner
5. Light switches of top and bottom of stairs for both townhomes.
Intake Approval  6/7/2019 FAIL
as per our conversation-please upload all apps for the separate townhouses, manual J's and revised site plan with correct info on it. Please make sure to name the drawings correctly and make sure you leave the bottom right corner open for our approved stamp. Once we get all the drawings and other info we will do the prescreen accordingly
Application received  6/3/2019 DONE
Application submitted via PDS Online on Jun 3 2019 8:12AM