Final | 8/30/2019 | 9/3/2019 | 9/3/2019 | A | PASS |
Brian Scoles
|
|
|
garage sliding door is unlocked Phone #: ###-#### Inspection requested via web by Randy Hart
|
Final | 8/29/2019 | 8/30/2019 | 8/30/2019 | A | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - no access to home left notice on front door
|
Mec-Aging Inspection | 7/29/2019 | 7/29/2019 | 7/29/2019 | | FAIL |
Brian Scoles
|
|
|
no calls- will expire permit next aging if no activity- needs called in for extension by contractor oif works still going on
|
Mec-Aging Inspection | 4/29/2019 | 4/29/2019 | 4/29/2019 | | FAIL |
Brian Scoles
|
|
|
contractor needs to schedule inspection when works completed- bld permit still open
|
Rough-in | 1/28/2019 | 1/30/2019 | 1/30/2019 | A | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - R/I ok
|
Pressure Test | 1/28/2019 | 1/30/2019 | 1/30/2019 | A | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - 20lb gas pressure test ok - tagged meter
|
Rough-in | 7/5/2018 | 7/5/2018 | 7/5/2018 | P | CANC |
Jack Reynolds
|
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
Rough-in | 6/29/2018 | 6/29/2018 | 6/29/2018 | P | FAIL |
Jack Reynolds
|
|
|
Ashley Phone #: ###-####- Need Man J. onsite- Cant find where dryer vent terminates- flex ducting has many kinks that need fixed- need to see access for furnace in ceiling and a platform big enough for performing service on unit M1305.1.3 appliances in attic- lineset has rips that need fixed
|
Pressure Test | 6/29/2018 | 6/29/2018 | 6/29/2018 | P | FAIL |
Jack Reynolds
|
|
|
Ashley Phone #: ###-####- Gauge would not zero- need inert tape at gas line penetration
|
Issue PAID IN FULL permit | | | 6/29/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/29/2018 | | DONE |
|
|
|
This permit was created on the web by Randy Hart
|
Override - Parcel Holds | 6/29/2018 | 1/1/1900 | 6/29/2018 | | |
|
|
|
Paid double fee for stop work order
|