Permit Information
Permit NumberBLD19-00727
StatusFinaled
Name PERIGEE GROUP LLC
Site Address 1290 W MYRTLE ST Unit: 110
Project NameFirst Interstate Bank T.I.
Customer Number 
ePlanReviewYes
Description
(FIRST INTERSTATE BANK – SUITE #110) This is a fully sprinklered and alarmed building for area and height increase. Permit is improvements to an existing 3,200 sq. ft. first floor shell space that is being finished out for the first time within an existing 5-story building. Approval is contingent upon adhering to the approved plans on file. Work to include: construction of interior partition walls, new accessible doors/hardware, new millwork, mechanical/plumbing/electrical work, and finishes in compliance with chapter 8 of the 2015 IBC. The space consists of a hospitality entry area, teller work stations, (4) offices, open office space, conference room, break area, IT room, Copy/Work Room, and ATM Night Drop. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. The building is type IIB over a type 1A podium per the special provisions of section 510.2/2015 IBC. **JHB**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/13/20201/14/20201/14/2020APASS
DetailsDave Hannah
After 8:15 am // Peter Phone #: ###-####
FIRE-Final Inspection1/13/20201/13/20201/13/2020PPASS
DetailsJim Page
Previously noted items have been corrected, final life fire safety inspection for area of work complete.
BLD-Final12/20/201912/23/201912/23/2019PCANC
DetailsDave Hannah
Peter Phone #: ###-####
FIRE-Final Inspection12/20/201912/23/201912/23/2019AFAIL
DetailsJim Page
Mag lock interface with fire alarm system has not been completed, as stated in past inspections on 13SEPT2019 and 21NOV2019, mag locks on egress doors need to release during general fire per international fire code. A seperate permit is required for any and all fire alarm system modifications.

Peter Phone #: ###-####
BLD-Final12/20/201912/20/201912/20/2019PNR
DetailsDave Hannah
call for access - final inspection for Permanent Occupancy // Peter Phone #: ###-####
FIRE-Final Inspection11/21/201911/21/201911/21/2019PFAIL
DetailsJim Page
Mag lock interface with fire alarm system has not been completed, as stated in past inspection on 13SEPT2019, mag locks on egress doors need to release during general fire per international fire code.

Travis Phone #: ###-####
BLD-Aging Inspection11/13/201911/13/201911/14/2019 PEND
DetailsDave Hannah
BLD-Final9/13/20199/13/20199/13/2019PPASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Travis Knutson
FIRE-Final Inspection9/13/20199/13/20199/13/2019PPART
DetailsJim Page
Previously noted items have been corrected, partial final inspection for life fire safety complete. Fire sprinkler inspection is complete, scope of work for fire alarm has been completed but mag locks have been installed and will be programmed by the tenant, per IFC chapter 10, access controled doors in the path of egress must release during general fire alarm, fire extinguisher will be placed in discussed location. 45 day TCO authorized by Ron Johnson with Boise Fire contingent upon mag lock release on fire alarm, a permit will be required for fire alarm modifications. Signature has been provided on sign off card for associated trades.

Phone #: ###-#### Inspection requested via web by Travis Knutson
BLD-Final9/12/20199/12/20199/12/2019PCANC
DetailsDave Hannah
Please call 30min prior to arrival to insure I''m onsite. Phone #: ###-#### Inspection requested via web by Travis Knutson
FIRE-Final Inspection9/12/20199/12/20199/12/2019PFAIL
DetailsJim Page
Plans inside space did not have city approved stamp. Existing exit sign still in place that is not lined up with any door, another exit sign has been added a short disatnce away from existing that is in the correct location, need exisitng exit sign removed. Ceiling tile not in place next to fire sprinkler head. Main entry has access control mag locks, per IFC chapter 10 of IFC, mag locks need to release under general fire alarm when associated with an egress door.

Please call 30min prior to arrival to insure onsite. Phone #: ###-#### Inspection requested via web by Travis Knutson
BLD-Ceiling Grid Inspection8/29/20198/29/20198/29/2019PPASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Jose Coronado
BLD-Framing/Rough-in6/12/20196/12/20196/12/2019PPASS
DetailsDave Hannah
Inspection requested via web by Jose Coronado
BLD-Framing/Rough-in6/6/20196/12/20196/12/2019APASS
DetailsDave Hannah
Inspection requested via web by Jose Coronado