Zoning Approval | 8/1/2019 | 8/1/2019 | 8/1/2019 | | PASS |
Josh Wilson
|
|
|
Ok to release Planning portion of bond
|
PubWorks Occupancy Approval | 7/30/2019 | 7/30/2019 | 7/30/2019 | | DONE |
Tiffany Lowery
|
|
|
|
BLD-Aging Inspection | 7/5/2019 | 7/5/2019 | 7/5/2019 | | PASS |
Jim Storey
|
|
|
esi has occ requist unfiled.
|
Print Occupancy Form | | | 5/15/2019 | | DONE |
|
|
|
|
Zoning Approval Temp | 3/11/2019 | 3/11/2019 | 3/11/2019 | | PASS |
Josh Wilson
|
|
|
270-day temp occ ok per BND19-00044
|
PubWorks Temp Occupancy Appr | 3/11/2019 | 3/11/2019 | 3/11/2019 | | DONE |
Tiffany Lowery
|
|
|
Bonding provided 03/11/2019. Ok to sign temp occupancy per Brian Murphy.
|
BLD-Final | 2/21/2019 | 2/21/2019 | 2/21/2019 | A | PASS |
Jim Storey
|
|
|
final ok perm.
|
BLD-Final | 2/20/2019 | 2/21/2019 | 2/21/2019 | A | PASS |
Jim Storey
|
|
|
Dave Phone #: ###-#### final ok perm.
|
BLD-Final | 1/29/2019 | 1/30/2019 | 1/30/2019 | A | PART |
Jim Storey
|
|
|
Chris ###-#### ok for tco// foam protected at exterior wall//fire stop spk boiller rm// adj doors 15 lbs//occ load sign// mat at 2nd floor.
|
Print Occupancy Form | | | 1/30/2019 | | DONE |
|
|
|
|
FIRE-Final Inspection | 1/29/2019 | 1/29/2019 | 1/29/2019 | P | PASS |
Troy Cobbley
|
|
|
Life safety passed.
Dave Phone #: ###-####
|
BLD-Final | 1/8/2019 | 1/9/2019 | 1/9/2019 | A | PASS |
Jim Storey
|
|
|
Dave Phone #: ###-#### temp occ ok for 2nd floor/ maintane protected exit access.
|
FIRE-Final Inspection | 1/8/2019 | 1/8/2019 | 1/8/2019 | P | PART |
Troy Cobbley
|
|
|
Life safety passed for the second floor. The fire alarm notification modification in the Lobby for the Link in Building 36 will need to be done prior to a phase 3 sign off.
second floor // Dave Phone #: ###-####
|
BLD-Framing/Rough-in | 1/3/2019 | 1/3/2019 | 1/3/2019 | P | PASS |
Jim Storey
|
|
|
Please call Robert; Locker room walls and gyp. ceiling. Phone #: ###-#### Inspection requested via web by Chris Fuhrman walls and ceilling
|
BLD-Ceiling Grid Inspection | 1/3/2019 | 1/3/2019 | 1/3/2019 | P | PASS |
Jim Storey
|
|
|
Please call Robert; Area C, 1st Floor Phone #: ###-#### Inspection requested via web by Chris Fuhrman
|
FIRE-Final Inspection | 12/27/2018 | 12/28/2018 | 12/28/2018 | P | FAIL |
Jim Page
|
|
|
Fire alarms are not complete, need fire alarms for phase 2 finaled. Phase 2 is not ready for life fire safety inspection.
Dave-2nd floor of phase 2 Phone #: ###-####
|
BLD-Ceiling Grid Inspection | 12/27/2018 | 12/27/2018 | 12/27/2018 | P | PASS |
Jim Storey
|
|
|
Please call Chris 1st Floor A ; B Phone #: ###-#### Inspection requested via web by Chris Fuhrman
|
BLD-Ceiling Grid Inspection | 12/20/2018 | 12/21/2018 | 12/21/2018 | P | PART |
Jim Storey
|
|
|
Please call Robert Snow - 1st floor areas A ; B Phone #: ###-#### Inspection requested via web by Chris Fuhrman ok west half/ pending tape and fire chalking at shaft nw
|
BLD-Ceiling Grid Inspection | 12/18/2018 | 12/19/2018 | 12/19/2018 | A | PASS |
Jim Storey
|
|
|
Please call Chris; Area 2C Phone #: ###-#### Inspection requested via web by Chris Fuhrman
|
BLD-Final | 12/17/2018 | 12/17/2018 | 12/17/2018 | P | PART |
Mike Jordan
|
|
|
Dave Phone #: ###-####. Ok to occupy the 3rd. floor, lobby and stairwell to link only.
|
BLD-Final | 12/14/2018 | 12/17/2018 | 12/17/2018 | P | CANC |
Mike Jordan
|
|
|
lobby 2nd and 1st and 3rd floor-Dave Phone #: ###-####
|
FIRE-Final Inspection | 12/14/2018 | 12/17/2018 | 12/17/2018 | P | PART |
Troy Cobbley
|
|
|
Phase 1 life safety passed.
lobby 2nd and 1st and 3rd floor-Dave Phone #: ###-####
|
BLD-Framing/Rough-in | 12/17/2018 | 12/17/2018 | 12/17/2018 | P | PASS |
Mike Jordan
|
|
|
1st. floor area C restrooms hardlids ok.
|
BLD-Framing/Rough-in | 12/17/2018 | 12/17/2018 | 12/17/2018 | A | CANC |
Mike Jordan
|
|
|
Please call Chris; 2nd floor restroom ceilings area C Phone #: ###-#### Inspection requested via web by Chris Fuhrman
|
BLD-Final | 12/14/2018 | 12/14/2018 | 12/14/2018 | P | CANC |
Mike Jordan
|
|
|
dave Phone #: ###-####
|
FIRE-Final Inspection | 12/14/2018 | 12/14/2018 | 12/14/2018 | P | FAIL |
Jim Page
|
|
|
Need signage leading from exterior to fire sprinkler riser room. Install fire lane signage as discussed. Provide notification over fire department connection, currently no bell or A/V device is installed. Stairwells need to be 100% complete before TCO can be authorized for life fire safety. Elevator smoke detectors report as a supervisor, detectors need to report as general alarm.
dave Phone #: ###-####
|
FIRE-Final Inspection | 12/13/2018 | 12/14/2018 | 12/14/2018 | A | FAIL |
Troy Cobbley
|
|
|
Todays inspection was for the third floor. Need additional emergency lighting in the first floor Main Lobby and the Entry, Need room signage, Need fire dept. access signage, Need the fire alarm system complete in all areas as per previous notes and for all areas in the common path of egress such as the Link, Provide sprinkler canopies in the path of egress, Provide key for knox box, Provide exit signs at the exterior exit doors at the bottom of the stair toweres
Dave Phone #: ###-####
|
BLD-Final | 12/12/2018 | 12/13/2018 | 12/13/2018 | P | CANC |
Mike Jordan
|
|
|
Dave Phone #: ###-####
|
FIRE-Final Inspection | 12/13/2018 | 12/13/2018 | 12/13/2018 | P | FAIL |
Jim Page
|
|
|
Need fire alarm and fire sprinklers finaled for Phase 1 TCO requested areas before life fire safety inspection will be performed.
Call Chris - Phase 1 Phone #: ###-#### Inspection requested via web by Chris Fuhrman
|
BLD-Ceiling Grid Inspection | 12/12/2018 | 12/13/2018 | 12/13/2018 | A | PASS |
Mike Jordan
|
|
|
Please call Chris; 1st floor lobby Phone #: ###-#### Inspection requested via web by Chris Fuhrman. 1st. floor lobby only ok.
|
BLD-Framing/Rough-in | 12/12/2018 | 12/12/2018 | 12/12/2018 | P | PASS |
Mike Jordan
|
|
|
Chris Phone #: ###-####. Hardlids, 1st floor restrooms in area 1A. 2nd.floor hardlids Room 201 excersise room ok.
|
BLD-Framing/Rough-in | 12/10/2018 | 12/11/2018 | 12/11/2018 | A | PASS |
Mike Jordan
|
|
|
Chris Phone #: ###-####. Hard lids at 2nd floor, area EC201 only ok.
|
FIRE-Conference | 11/28/2018 | 11/28/2018 | 11/28/2018 | A | DONE |
Jim Page
|
|
|
Noted that office furniture is still being placed on level 3 after GC notification that office furniture was to not be set until active fire protection is in place, no fire sprinklers are active and no fire alarms are active. Floor is being loaded with extra fuel without any active automatic fire protection in place.
|
BLD-Framing/Rough-in | 11/27/2018 | 11/27/2018 | 11/27/2018 | P | PASS |
Jim Storey
|
|
|
Please call Chris Area 2C RR hard ceiling, corridor 101 hard ceiling Phone #: ###-#### Inspection requested via web by Chris Fuhrman
|
BLD-Ceiling Grid Inspection | 11/26/2018 | 11/26/2018 | 11/26/2018 | P | PASS |
Jim Storey
|
|
|
Chris Phone #: ###-#### 2nd floor areas a and b
|
BLD-Ceiling Grid Inspection | 11/19/2018 | 11/20/2018 | 11/20/2018 | A | DEFR |
Jim Sly
|
|
|
Chris Phone #: ###-#### Notified Chris..............
|
BLD-Framing/Rough-in | 11/15/2018 | 11/15/2018 | 11/15/2018 | P | PASS |
Jim Storey
|
|
|
Chris Phone #: ###-#### hard ceillings 2nd floor/ restarm west, stair east
|
FIRE-Conference | 11/15/2018 | 11/15/2018 | 11/15/2018 | A | DONE |
Jim Page
|
|
|
Had a previous conversation with GC about installing office furniture before fire sprinklers and fire alarms are active. Discussed with Ron Johnson, placing of office furniture is not allowed, office furniture has been installed on level 3 after conversation stating that funiture is not to be installed. No other office furniture is authorized. The GC has been notified verbally that no office furniture is to be installed due to the increased fuel load that the furniture presents. If more office furniture is installed after this entry then the project will have a stop work notice placed and the project will be red tagged, this action is supported per conversation with Ron Johnson, Assistant Fire Marshall.
|
BLD-Framing/Rough-in | 11/13/2018 | 11/13/2018 | 11/14/2018 | P | PART |
Jim Storey
|
|
|
Chris Phone #: ###-#### 1st floor restarms ceillings ok 2nd floor shafts sealled// expantinon joint in stair encloser need listing.
|
Print Occupancy Form | | | 11/14/2018 | | |
|
|
|
|
Fees Due Hold | 11/6/2018 | | 11/13/2018 | | DONE |
Christina Prado
|
|
|
|
BLD-Framing/Rough-in | 11/5/2018 | 11/5/2018 | 11/5/2018 | P | PASS |
Jim Storey
|
|
|
Chris Phone #: ###-#### stair 1# and 2nd floor restaroom 2
|
Fees Due Hold | 11/5/2018 | | 11/5/2018 | | DONE |
Tiffany Carson-Herker
|
|
|
|
BLD-Framing/Rough-in | 11/2/2018 | 11/2/2018 | 11/2/2018 | P | PASS |
Jim Storey
|
|
|
Chris Phone #: ###-#### 3rd floor 80 % ok to drop ceilling/ shafts ok
|
BLD-Framing/Rough-in | 10/31/2018 | 10/31/2018 | 10/31/2018 | P | PART |
Jim Storey
|
|
|
Chris Phone #: ###-#### shafts west end ok
|
Fees Due Hold | 10/9/2018 | | 10/31/2018 | | DONE |
Brittany Hill
|
|
|
|
BLD-Foundation | 10/29/2018 | 10/30/2018 | 10/30/2018 | A | PASS |
Jim Storey
|
|
|
Dave-reinforcing rebar Phone #: 208-631-lab on grade
|
BLD-Framing/Rough-in | 10/26/2018 | 10/29/2018 | 10/29/2018 | A | PART |
Jim Storey
|
|
|
Chris Phone #: ###-#### hard ceilling first secnond floors ok up to stairs ok/ restarooms ok
|
BLD-Energy code compliance | 10/24/2018 | 10/24/2018 | 10/24/2018 | P | PASS |
Jim Storey
|
|
|
Chris Phone #: ###-#### backing ok in restarooms/ insulation on walk bridge ok// framing exterior sides ok
|
BLD-Framing/Rough-in | 10/18/2018 | 10/18/2018 | 10/18/2018 | P | PASS |
Jim Storey
|
|
|
Chris-per Chris-inspection has nothing to do with the plan mod Phone #: ###-#### all exterior walls ok to cover/ elavator ok to cover/ ceilling 3 rd floor west half ok.
|
Plan assigned to (CDM) | 10/12/2018 | 10/12/2018 | 10/18/2018 | | PASS |
Carl D Madsen
|
|
|
Plan Mod 3 - Revisions to Fitness area locker rooms to accommodate private towel off space at each shower stall, including one shower and towel off with ADA clearance for each locker room. The west (left) sides of the room stayed predominantly the way they were. The locker areas themselves did not change. Indirect circulation was removed to accommodate pushing the shower/restroom areas on the east (right) out to where the indirect circulation was before, while leaving the east wall that separated the locker area from fitness area (i.e, fitness area did not change). Door alcoves consisting of doors with push/pull handles and closers (no latch) were incorporated for line of site privacy at the entrances, since lost the indirect circulation that previously provided line of site privacy.
|
Routing - PLAN CHECK | 10/18/2018 | | 10/18/2018 | | PASS |
Carl D Madsen
|
|
|
|
CHANGE STATUS TO (ISS) | | | 10/18/2018 | | DONE |
|
|
|
plan mod Micron
|
BLD-Framing/Rough-in | 10/15/2018 | 10/15/2018 | 10/15/2018 | P | PART |
Jim Storey
|
|
|
Chris-as per Chris-thisinspection does not have anything to do with the plan mod that was turned in Phone #: ###-#### lobby 1st and 2nd floors insulation ok// south wall pending insulation and vappor barrior at canopy.
|
Plan Modification Accepted | | | 10/12/2018 | | DONE |
|
|
|
Plan Mod 3 - Revisions to Fitness area locker rooms to accommodate private towel off space at each shower stall, including one shower and towel off with ADA clearance for each locker room. The west (left) sides of the room stayed predominantly the way they were. The locker areas themselves did not change. Indirect circulation was removed to accommodate pushing the shower/restroom areas on the east (right) out to where the indirect circulation was before, while leaving the east wall that separated the locker area from fitness area (i.e, fitness area did not change). Door alcoves consisting of doors with push/pull handles and closers (no latch) were incorporated for line of site privacy at the entrances, since lost the indirect circulation that previously provided line of site privacy.
|
BLD-Energy code compliance | 10/8/2018 | 10/8/2018 | 10/8/2018 | P | PASS |
Jim Storey
|
|
|
Chris Phone #: ###-#### 3rd floor shaft tops ok// ok to proceed with outsde membrane and fire stopping// hard ceilling break rm 3rd fl se corner.
|
Fees Due Hold | 10/7/2018 | | 10/8/2018 | | DONE |
Tiffany Carson-Herker
|
|
|
|
Plan assigned to (CDM) | 9/19/2018 | 9/19/2018 | 10/5/2018 | | PASS |
Carl D Madsen
|
|
|
plan mod
|
CHANGE STATUS TO (ISS) | | | 10/5/2018 | | DONE |
|
|
|
|
Print Occupancy Form | | | 10/5/2018 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 9/26/2018 | | 10/5/2018 | | PASS |
Carl D Madsen
|
|
|
|
Routing - MECHANICAL | 9/26/2018 | | 10/4/2018 | | PASS |
Troy James
|
|
|
|
BLD-Framing/Rough-in | 10/3/2018 | 10/3/2018 | 10/3/2018 | P | PASS |
Jim Storey
|
|
|
Chris Phone #: ###-#### top of shafts13 and 15 3rd/top 12 on 2nd/ restarooms 3 rd ceillings ok to cover
|
BLD-Framing/Rough-in | 10/1/2018 | 10/1/2018 | 10/1/2018 | P | PART |
Jim Storey
|
|
|
Chris Phone #: ###-#### 2nd floor #7 1 in membrane missing//2nd floor #5 and #9 core and 5/8 exstend to beam web/ 3 fl #13 an #15 complet top of shaft assembly./3 fl #13 and 15 exterior membrane.
|
BLD-Foundation | 9/27/2018 | 9/27/2018 | 9/28/2018 | P | PASS |
Jim Storey
|
|
|
Dave-slab on grade-reinforcement for loading dock Phone #: ###-####
|
Routing - PLUMBING | 9/26/2018 | | 9/27/2018 | | PASS |
Daryl Spivey
|
|
|
Per plan and ISPC.
|
BLD-Wall Bracing | 9/20/2018 | 9/20/2018 | 9/20/2018 | P | PASS |
Jim Storey
|
|
|
Chris-per Chris does not have anything to do with the plan mod Phone #: ###-#### ok to cover.
|
BLD-Framing/Rough-in | 9/20/2018 | 9/20/2018 | 9/20/2018 | P | PASS |
Jim Storey
|
|
|
Chris-per Chris does not have anything to do with the plan mod Phone #: ###-#### rain ledder/ ele under floor// pic flor to floor/ pending as noted on site
|
Telephone call | | | 9/20/2018 | | DONE |
|
|
|
called Paul to let know that none of the sub permits are attached to the building permit
|
Plan Modification Accepted | | | 9/19/2018 | | DONE |
|
|
|
Plan Modification (2) application accepted for modification to return air shafts to comply with code where plumbing lines were installed within.
|
BLD-Framing/Rough-in | 9/13/2018 | 9/14/2018 | 9/14/2018 | A | PASS |
Jim Storey
|
|
|
Exterior walls section C; North, East and South. Exterior wall North Insulation 1st floor; 3rd Floor Shafts 5 ,6, 7 ; 9; Second Floor Shafts 1 ; 8; Restroom 307 ; 308 walls Phone #: ###-#### Inspection requested via web by Chris Fuhrman
|
BLD-Framing/Rough-in | 9/13/2018 | 9/13/2018 | 9/13/2018 | P | CANC |
Mike Jordan
|
|
|
Exterior walls section C; North, East and South. Exterior wall North Insulation 1st floor; 3rd Floor Shafts 5 & 9; Second Floor Shafts 1 & 8; Restroom 307 & 308 walls Phone #: ###-#### >> Inspection requested via web by Chris Fuhrman Inspection cancelled from web by: Chris Fuhrman
|
BLD-Framing/Rough-in | 9/13/2018 | 9/13/2018 | 9/13/2018 | P | CANC |
Mike Jordan
|
|
|
Exterior walls section C; North, East and South. Exterior wall North Insulation 1st floor; 3rd Floor Shafts 5 & 9; Second Floor Shafts 1 & 8; Restroom 307 & 308 walls Phone #: ###-#### >> Inspection requested via web by Chris Fuhrman Inspection cancelled from web by: Chris Fuhrman
|
BLD-Framing/Rough-in | 9/11/2018 | 9/12/2018 | 9/12/2018 | A | CANC |
Jim Storey
|
|
|
Area C Exterior Walls (N, E & S); Insulation / Vapor Barrier North Wall of Electrical 1st Floor Phone #: ###-#### >> Inspection requested via web by Chris Fuhrman Inspection cancelled from web by: Chris Fuhrman
|
Plan assigned to (CDM) | 8/21/2018 | 8/21/2018 | 9/6/2018 | | PASS |
Carl D Madsen
|
|
|
|
Routing - PLAN CHECK | 8/23/2018 | | 9/6/2018 | | PASS |
Carl D Madsen
|
|
|
|
Permit Ready to Issue | | | 9/6/2018 | | DONE |
|
|
|
|
CHANGE STATUS TO (ISS) | | | 9/6/2018 | | DONE |
|
|
|
|
BLD-Wall cover | 9/5/2018 | 9/5/2018 | 9/5/2018 | P | PASS |
Jim Storey
|
|
|
Please call Chris when in route Phone #: ###-#### Inspection requested via web by Chris Fuhrman core board framing/ pipe wrap./ ok on 3dr and 2nd floors at rtu 5 and 9.
|
BLD-Wall cover | 8/28/2018 | 8/29/2018 | 8/29/2018 | A | FAIL |
Jim Storey
|
|
|
Please call chris when in route - firewalls and shafts Phone #: ###-#### Inspection requested via web by Chris Fuhrman
|
BLD-Conference | 8/24/2018 | 8/24/2018 | 8/24/2018 | P | PASS |
Jim Storey
|
|
|
Review Stairway Door and Shaft Wall Details Please call Chris Fuhrman when in route Thank you, Phone #: ###-#### Inspection requested via web by Chris Fuhrman noted w/chris submitals in his office.
|
Routing - PUBLIC WORKS | 8/23/2018 | | 8/24/2018 | | PASS |
Rachael Beierle
|
|
|
Purchase sewer capacity seperate. No additional fees for fixture change.
|
CHANGE STATUS TO (ISS) | | | 8/23/2018 | | DONE |
|
|
|
change status to iss so can schedule inspections online. ok per Rita
|
Plan Modification Accepted | | | 8/21/2018 | | DONE |
|
|
|
Plan Mod - replace water closets with urinals, 1st, 2nd & 3rd floor
|
BLD-Wall cover | 8/20/2018 | 8/20/2018 | 8/20/2018 | P | PART |
Jim Storey
|
|
|
Fire wall 3rd floor section a and framing 3rd floor section c Phone #: ###-#### Inspection requested via web by Chris Fuhrman west shaft tops ok/ east part.
|
BLD-Framing/Rough-in | 8/16/2018 | 8/17/2018 | 8/17/2018 | A | NR |
Jim Storey
|
|
|
3rd floor framing area C // Dave Perkins Phone #: ###-#### c/n isued// provide listingforhead of wall assembly and material used.//s/fd instaled 1/2 in 1/2 out of wall assemblies provide listing./provide core board wall/shaft listing for aplacation at door jambs/ bar joist membrane penatrations.// provide fire stopping listings and products from all trades for all penatrations.
|
BLD-Foundation | 8/15/2018 | 8/16/2018 | 8/16/2018 | A | PASS |
Jim Storey
|
|
|
rebar // Dave Phone #: ###-####
|
BLD-Conference | 8/13/2018 | 8/14/2018 | 8/14/2018 | P | PASS |
Jim Storey
|
|
|
Meet to review shaft conflicts with CTA 1:30PM OK per Jim Storey Phone #: ###-#### Inspection requested via web by Chris Fuhrman
|
BLD-Energy code compliance | 8/9/2018 | 8/10/2018 | 8/10/2018 | A | PASS |
Jim Storey
|
|
|
Dave Phone #: ###-#### 1st floor ok to cover exterior walls and interior/ not ok for cover shafts and stair enclosers.
|
BLD-Framing/Rough-in | 7/18/2018 | 7/19/2018 | 7/19/2018 | A | PASS |
Jim Storey
|
|
|
Levels 2 & 3 interior - Dave Phone #: ###-#### ok to cover noter on plan all but shaft areas
|
BLD-Framing/Rough-in | 7/12/2018 | 7/12/2018 | 7/12/2018 | P | FAIL |
Jim Storey
|
|
|
Dave Phone #: ###-#### 2nd floor clip to studs screws grid a and L
|
BLD-Framing/Rough-in | 7/10/2018 | 7/10/2018 | 7/10/2018 | P | PASS |
Jim Storey
|
|
|
3rd fl ext framing - Dave Phone #: ###-#### exterior walls as noted ok to insulate// shaft elavator and stair encloser rated walls need evauated for clearance.
|
CHANGE STATUS TO (ISS) | | | 6/13/2018 | | DONE |
|
|
|
|
(F) Reprint permit | | | 6/13/2018 | | DONE |
|
|
|
|
Print Occupancy Form | | | 6/13/2018 | | DONE |
|
|
|
|
Issue & PRINT to be Invoiced | | | 6/11/2018 | | DONE |
|
|
|
|
Print Occupancy Form | | | 6/11/2018 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 6/11/2018 | | DONE |
|
|
|
Need ACHD
|
CHANGE STATUS TO (RDY) | | | 6/11/2018 | | DONE |
|
|
|
change status back to RDY, need ACHD
|
Plan assigned to (CDM) | 4/9/2018 | 4/9/2018 | 6/9/2018 | | PASS |
Carl D Madsen
|
|
|
Micron Office Bldg. New
|
Routing - PLAN CHECK | 5/16/2018 | | 6/9/2018 | | PASS |
Carl D Madsen
|
|
|
|
Routing Off Site - STRUCTURAL | 5/16/2018 | | 6/9/2018 | | PASS |
Carl D Madsen
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/9/2018 | | DONE |
|
|
|
|
Route to Impact Fee Review | 5/7/2018 | 5/10/2018 | 5/8/2018 | | PASS |
Eric Bilimoria
|
|
|
Review requested for Commercial Permit
|
Routing - FIRE | 4/9/2018 | 4/9/2018 | 5/7/2018 | | PASS |
Erika Akin
|
|
|
Attached comments to case
|
1st review completed | | | 5/7/2018 | | FAIL |
|
|
|
|
Routing Off Site - STRUCTURAL | 4/9/2018 | | 5/5/2018 | | FAIL |
Carl D Madsen
|
|
|
|
Routing - PLAN CHECK | 4/9/2018 | | 5/5/2018 | | FAIL |
Carl D Madsen
|
|
|
|
Routing - MECHANICAL | 4/9/2018 | | 4/17/2018 | | PASS |
Troy James
|
|
|
|
Routing - PLUMBING | 4/9/2018 | | 4/12/2018 | | PASS |
Bill VanDegrift
|
|
|
per plans and ISPC
|
Routing - Erosion and Sediment | 4/9/2018 | | 4/10/2018 | | PASS |
Andy J. Long
|
|
|
ESC plan reviewed and ESC permit issued with GRD17-00087. See ESC18-00006. No duplicate ESC permit required.
|
Intake Approval | | | 4/9/2018 | | PASS |
|
|
|
|
Routing - Addressing | 4/9/2018 | | 4/9/2018 | | PASS |
Doug Chausow
|
|
|
|
Routing - PUBLIC WORKS | 4/9/2018 | | 4/9/2018 | | PASS |
Rachael Beierle
|
|
|
Purchase consumption. No impact fee for sewer.
|
Plans ACCEPTED BY PLAN TECH | | | 4/9/2018 | | DONE |
Christina Prado
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 4/9/2018 | | DONE |
Christina Prado
|
|
|
|
Routing - Design Review | 4/9/2018 | | 4/9/2018 | | PASS |
Sarah Schafer
|
|
|
DRH18-00035 - Approved per DRH18-00035.
|
Routing - PLANNING | 4/9/2018 | | 4/9/2018 | | PASS |
David Moser
|
|
|
See DRH18-00035
|
Routing PW Environmental | 4/9/2018 | | 4/9/2018 | | PASS |
Rick Christenson
|
|
|
|
Routing PW Solid Waste | 4/9/2018 | | 4/9/2018 | | PASS |
Evan Carpenter
|
|
|
|
Routing PW Sewer Design | 4/9/2018 | | 4/9/2018 | | PASS |
DeAnn Brown
|
|
|
|
Routing PW Drainage | 4/9/2018 | | 4/9/2018 | | PASS |
Brian Murphy
|
|
|
PART OF MASTER PLAN APPROVED
|
Intake Approval | | | 3/29/2018 | | FAIL |
Julie Romig
|
|
|
1. Completed Form 310 with design professional and owner information filled out and signed by owner.
2. Verification of Legal Lot and Parcel form signed by PDS staff. Contact Todd Tucker at TTucker@cityofboise.org.
3. Site specific fire flow at hydrants letter.
4. Site Drainage Report
5. Drainage System Operation & Maintenance Plan.
|
Application received | | | 3/27/2018 | | DONE |
|
|
|
Application submitted via PDS Online on Mar 27 2018 4:05PM
|