Final | 12/20/2018 | 12/20/2018 | 12/20/2018 | P | PASS |
Tom Saunders
|
|
|
May be at Innovative Air. Please call when you are en route and I will make sure to be here. Phone #: ###-#### Inspection requested via web by Jason Parke....ok to final
|
Final | 12/19/2018 | 12/19/2018 | 12/19/2018 | P | NR |
Tom Saunders
|
|
|
Final service inspection Phone #: ###-#### Inspection requested via web by Jason Parke...
spoke with jobsite journeyman and said lift station not complete will reschedule for next day when job complete
|
Final | 12/14/2018 | 12/17/2018 | 12/17/2018 | A | PART |
Tom Saunders
|
|
|
Roof equipment, exterior, gym, gym offices, bathrooms Phone #: ###-#### Inspection requested via web by Jason Parke...
remaining to inspect: lift station, service, verify lock outs on discussed circuits
|
Electrical Rough-In | 12/11/2018 | 12/11/2018 | 12/11/2018 | P | PASS |
Tom Saunders
|
|
|
Hallways ceiling cover Phone #: ###-#### Inspection requested via web by Jason Parke..
hall grid ok LV tray bonding verified as well
|
Electrical Rough-In | 12/5/2018 | 12/5/2018 | 12/5/2018 | A | PASS |
Tom Saunders
|
|
|
PE Office ceiling inspection Phone #: ###-#### Inspection requested via web by Jason Parke... ok to cover
|
Electrical Rough-In | 11/28/2018 | 11/29/2018 | 11/29/2018 | A | PASS |
Tom Saunders
|
|
|
Inspect rough in for cover. Phone #: ###-#### Inspection requested via web by Jeremy Cloud... classroom ceiling grids x 2 ok to cover
|
Electrical Rough-In | 11/13/2018 | 11/13/2018 | 11/13/2018 | A | PASS |
Tom Saunders
|
|
|
Hard lids in bathrooms Phone #: ###-#### Inspection requested via web by Jason Parke... ok to cover
|
Electrical Rough-In | 11/5/2018 | 11/5/2018 | 11/5/2018 | P | PASS |
Tom Saunders
|
|
|
De-energize main switch board, adding 4 breakers and terminating feeders, re-energize approximately 3:30. Will call when getting close to re-energizing Phone #: ###-#### Inspection requested via web by Jason Parke... new sub feeds to existing service ok...4 breakers added
|
Electrical Rough-In | 10/31/2018 | 10/31/2018 | 10/31/2018 | P | PASS |
Tom Saunders
|
|
|
Storage room 104 walls and ceiling. Phone #: ###-#### Inspection requested via web by Jason Parke...ok to cover
|
Electrical Rough-In | 10/29/2018 | 10/29/2018 | 10/29/2018 | A | PASS |
Tom Saunders
|
|
|
west side hallway ways Phone #: ###-#### Inspection requested via web by Jason Parke... west side hallway ok to cover
|
Electrical Rough-In | 10/25/2018 | 10/25/2018 | 10/25/2018 | P | PASS |
Tom Saunders
|
|
|
Hallway ceiling cover Grounding Phone #: ###-#### Inspection requested via web by Jason Parke...hallway ceiling and east side of walls...discussed grounding of cable tray and lv board
|
Electrical Rough-In | 10/24/2018 | 10/24/2018 | 10/24/2018 | P | PASS |
Eric Story
|
|
|
PE Office area walls and hard lids Phone #: ###-#### Inspection requested via web by Jason Parke Walls and lids in P.E offices IT and storage as well as out canopy(EC stated grounding for IT rack will eb surface mounted to a bonded beam and accesible
|
Electrical Rough-In | 10/22/2018 | 10/22/2018 | 10/22/2018 | P | PASS |
Eric Story
|
|
|
Underground- stubs inspected on both ends, finished connecting Phone #: ###-#### Inspection requested via web by Jason Parke L/V tie in ok to cover
|
Electrical Rough-In | 10/18/2018 | 10/18/2018 | 10/18/2018 | A | PASS |
Tom Saunders
|
|
|
Gym walls for cover and roof penetrations Phone #: ###-#### Inspection requested via web by Jason Parke...ok to cover designated areas...discussed 2 vestibules in GYM that need built once sheeted and sheetrock-1 E-light in ea
|
Electrical Rough-In | 10/17/2018 | 10/17/2018 | 10/17/2018 | A | PASS |
Tom Saunders
|
|
|
Bathroom and storage wall cover and vestibule ceiling cover Phone #: ###-#### Inspection requested via web by Jason Parke...ok to cover areas stated
|
Electrical Rough-In | 10/11/2018 | 10/11/2018 | 10/11/2018 | P | PASS |
Tom Saunders
|
|
|
Rough in at one interior wall for cover so we can mount panels. Opposite side has already been inspected. Phone #: ###-#### Inspection requested via web by Jason Parke...panel rm wall...panel location
|
Electrical Rough-In | 10/1/2018 | 10/1/2018 | 10/1/2018 | P | PASS |
Mark Moncarr
|
|
|
Classrooms walls rough-in Exterior boxes in brick Phone #: ###-#### Inspection requested via web by Jason Parke Ok cover lid and walls 2 classrooms.
|
Electrical Rough-In | 9/24/2018 | 9/25/2018 | 9/25/2018 | A | PASS |
Daryl DeGrange
|
|
|
Parapet walls rough-in Phone #: ###-#### Inspection requested via web by Jason Parke Parapet walls rough-in ok cover
|
Electrical Rough-In | 9/12/2018 | 9/12/2018 | 9/12/2018 | P | DONE |
Eric Story
|
|
|
Exterior wall rough in and lift station Phone #: ###-#### Inspection requested via web by Jason Parke Conference needed
|
Conference | 9/12/2018 | 9/12/2018 | 9/12/2018 | P | DONE |
Eric Story
|
|
|
Exterior wall rough in and lift station Phone #: ###-#### Inspection requested via web by Jason Parke Discussed a seal off once entrying building from methane gas and will be installed within 18" from when it enters the room
|
Electrical Rough-In | 8/8/2018 | 8/8/2018 | 8/8/2018 | P | PASS |
Tom Saunders
|
|
|
Underground stub-ups at panel at northwest corner of the new slab area. Rock inspected/took pictures of conduits close, we just needed to glue on 90''s and nipples to get to above slab. Phone #: ###-#### Inspection requested via web by Jason Parke...underslab complete...ok to cover
|
Electrical Rough-In | 8/1/2018 | 8/2/2018 | 8/2/2018 | A | PASS |
Rock A. Hudson
|
|
|
Underground branch circuit homeruns. As early as possible please Phone #: ###-#### Inspection requested via web by Jason Parke Underslab branch conduits rough in ok cover
|
Electrical Rough-In | 7/25/2018 | 7/26/2018 | 7/26/2018 | A | PASS |
Tom Saunders
|
|
|
Underground. Just 2- 3/4" conduits going across the gym. Phone #: ###-#### Inspection requested via web by Jason Parke...ok to cover
|
Electrical Rough-In | 7/24/2018 | 7/24/2018 | 7/24/2018 | P | PASS |
Tom Saunders
|
|
|
underground- AM if possible Phone #: ###-#### Inspection requested via web by Jason Parke...data pipes and fire alarm...ok to cover
|
Issue PAID IN FULL permit | | | 6/19/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/19/2018 | | DONE |
|
|
|
This permit was created on the web by Kevin Perez
|
First Notice | 12/20/2018 | 12/20/2018 | | | |
Tom Saunders
|
|
|
|