Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberESC17-00895
StatusFinaled
Name JASON JONES
Site Address 2407 S ORMOND ST
Project NameOrmand Street Cottages
Customer Number 
ePlanReviewNo
Description
Site development with sewer, water, irrigation, asphalt paving curb and gutter sidewalks. SWPPP prepared for project. Permit signage, consruction entrance, concrete washout, and DI protection on Ormand Street is required. Site preparation inspection is required.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection11/26/201911/26/201911/26/2019 CANC
DetailsMichael Zawacki
DOC - Permit Finaled11/26/201911/26/201911/26/2019PPASS
DetailsMichael Zawacki
General Inspection10/11/201910/11/201910/14/2019 PASS
DetailsAndy J. Long
All homes are complete in sub, common areas stabilized/landsacepd. Once DI bags are removed the ESC permit may be finaled. RP notified.

General Inspection8/26/20198/26/20198/26/2019 PASS
DetailsMichael Zawacki
All home exteriors completed, site has been landscaped. No ESC issues.
General Inspection7/9/20197/9/20197/9/2019 PASS
DetailsMichael Zawacki
Homes in rear of development completed and landscaped. All concrete work looks completed, all work is framing or inside homes. Trash is contained, no ESC issues at site. All lots currently under construction.
Tracking Control5/22/20195/24/20195/24/2019APASS
DetailsMichael Zawacki
Curtis clean sweep on site.
Tracking Control5/20/20195/22/20195/22/2019AFAIL
DetailsMichael Zawacki
Contractor only cleaned small area. Sent message to Jason Jones, listed RP.
Follow up scheduled.
General Inspection5/17/20195/20/20195/20/2019PFAIL
DetailsMichael Zawacki
Pump truck drove in mud and made mess with trackout. Crew sweeping, follow up scheduled for 5-22
General Inspection5/17/20195/17/20195/17/2019 CANC
DetailsAndy J. Long
General Inspection4/1/20194/1/20194/1/2019 PASS
DetailsMichael Zawacki
Work on homes in rear. Foundation at front complete, no new work. Inlet protection installed and about 1/4th full.
Conference2/13/20192/13/20192/13/2019PDONE
DetailsAndy J. Long
new Neighborworks contact info for project:

- Joe 208.941.3904

- Shelly 208.258.6220
General Inspection1/4/20191/4/20191/7/2019 PASS
DetailsAndy J. Long
Storm drains have sediment protection. Ecopan concrete washout on site and has remaining capacity. Trackout within subdivsion occuring, no trackout to Ormund Street. SFHs now in progress and permitted seperately.
General Inspection11/19/201811/19/201811/19/2018PPASS
DetailsMichael Zawacki
WIP on multiple homes and grading. oundation poured, did not see washout on site, no sign of dumped washout. No dirt leaving site, trackout on road inside site.
General Inspection10/12/201810/12/201810/15/2018 PASS
DetailsMichael Zawacki
No new activity, growth on lots and stable.
General Inspection8/27/20188/27/20188/27/2018 PASS
DetailsMichael Zawacki
No new activity.
Aging Inspection7/10/20187/10/20187/10/2018 PASS
DetailsMichael Zawacki
No new work. Lots all have survey stakes and no activity. Weeds are starting to grow providing stabalization.
General Inspection5/10/20185/29/20185/29/2018PPASS
DetailsMichael Zawacki
Roads and sidewalks complete. Site is sitting idle. Area is stabalized.
General Inspection5/9/20185/10/20185/10/2018PPASS
DetailsAndy J. Long
No new activity. Subdivision infrastructure complete, storm drain has sediment protection. Permit sign posted. Lots have vegetation growing. Approved.
General Inspection11/14/201711/15/201711/15/2017APASS
DetailsMichael Zawacki
see if work has occurred; call JEC about project
Utilities complete. Road, curb & gutter, and sidewalk installed. No work on homesites has begun.
Issue & PRINT permit COM  8/2/2017 DONE
Routing - Erosion and Sediment7/25/2017 7/25/2017 DONE
DetailsAndy J. Long
ESC plan/SWPPP approved. Valid PD and RP designated. Site preparation inspection is required, call ###-#### to schedule.
Application received  7/13/2017 DONE
Application submitted via PDS Online on Jul 13 2017 4:45PM