Permit Information
Permit NumberBLD19-02398
StatusFinaled
Name PRUSIK CONSTRUCTION
Site Address 4620 W OVERLAND RD
Project NameAndrade's Restaurant
Customer Number 
ePlanReviewYes
Description
(ANDRADE'S RESTAURANT) **PLAN MODIFICATION 5/21/20 TO MODIFY DOOR 101F AND REMOVE OPERABLE HARDWARE FROM DOOR. THIS DOOR SHALL NOT BE USED AS AN EXIT. NO EXIT SIGN PERMITTED ABOVE THIS DOOR.** Permit for the construction of a new 6,030 sq. ft. restaurant with work to include a concrete foundation, slab on grade floor, and wood framed type VA structure above along with related site improvements, per the approved plans. Work to include new electrical, new plumbing and new mechanical systems per the approved plans. Special inspections required per attached Form 310 for concrete placement. This building is fully fire sprinklered for A2 occupancy over 100. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits, and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **JHB**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/1/20207/1/20207/1/2020PPASS
DetailsTell Riley
Call Wes Phone #: ###-#### Inspection requested via web by Wes palm//CDHD signature was confirmed via photo from Wes//final is now complete for occupancy//
BLD-Final6/23/20206/23/20206/23/2020PPART
DetailsTell Riley
Please Call Wes Palm Phone #: ###-#### Inspection requested via web by Wes palm//architect provided clarification on handrails and guard//need CDHD approval for final//Temp ok until CDHD complete//
BLD-Final6/22/20206/22/20206/22/2020PNR
DetailsTell Riley
Please call Wes Palm at ###-#### Phone #: ###-#### Inspection requested via web by Wes palm/used as conference/walk through//need information from architect regard the guardrail at the back of building and one side of handrail at stairs 34" and other side 36"//
FIRE-Final Inspection6/18/20206/19/20206/19/2020APASS
DetailsTroy Cobbley
Life safety passed.

Please Call Wes @ ###-#### Phone #: ###-#### Inspection requested via web by Wes palm
BLD-Energy code compliance4/29/20204/30/20204/30/2020APART
DetailsTell Riley
Insulation / Cover Inspection at Fire Riser Room Phone #: ###-#### Inspection requested via web by Wes palm//add insulation as discussed//architect provided 1hr detail//light needs to surface mount//door needs to be 1hr per plans, current door is not rated//
BLD-Energy code compliance3/25/20203/26/20203/26/2020PPART
DetailsTell Riley
Final insulation inspection for cover at attic area. Phone #: ###-#### Inspection requested via web by Wes palm//ok in attic area//
BLD-Energy code compliance3/23/20203/24/20203/24/2020APART
DetailsTell Riley
Insulation inspection for cover at tower and bar locations. Phone #: ###-#### Inspection requested via web by Wes palm//tower and bar area ok//
BLD-Energy code compliance3/19/20203/20/20203/20/2020PCANC
DetailsTell Riley
Partial inspection of insulation for cover at tower and bar area lid.
Please call Wes P with any concerns Phone #: ###-#### Inspection requested via web by Wes palm
BLD-Wall cover3/12/20203/13/20203/13/2020PPART
DetailsTell Riley
Inspection for cover at main floor exterior walls and seating area lid. Phone #: ###-#### Inspection requested via web by Wes palm//ok to cover walls--do not cover fire riser room--need rated assembly documents//ok to cover lid in dining area pending fire sprinkler approval//
BLD-Framing/Rough-in3/4/20203/5/20203/5/2020PPASS
DetailsTell Riley
Please Call Wes with any questions at the number listed above. Phone #: ###-#### call 30 minutes//ok to insulate//a few corrections and interior shear needs verified//
BLD-Framing/Rough-in3/3/20203/4/20203/4/2020PNR
DetailsTell Riley
Please Call Wes with any questions at the number listed above. Phone #: ###-#### Inspection requested via web by Wes palm//multiple framing corrections, Wes has notes and plans have been marked//will come back 3/4//
BLD-Wall Bracing2/11/20202/12/20202/12/2020PPART
DetailsTell Riley
RE-INSPECTION for completed Items including noted strapping at windows per details on plans ; noted truss blocking per truss details and plans at strapping required on roof decking. Phone #: ###-#### Inspection requested via web by Wes Harrison//truss blocking installed//strapping installed and nailed per plans// exterior nailing and shear ok//
BLD-Wall Bracing2/10/20202/11/20202/11/2020PCANC
DetailsTell Riley
RE-INSPECTION for completed Items including noted strapping at windows per details on plans & noted truss blocking per truss details and plans at strapping required on roof decking. Phone #: ###-#### >> Inspection requested via web by Wes Harrison Inspection cancelled from web by: Wes Harrison
BLD-Wall Bracing2/6/20202/7/20202/7/2020PPART
DetailsTell Riley
Hoping to also have you look at small insulated areas before cover at TPO areas. Phone #: ###-#### Inspection requested via web by Wes palm//flat roof and floor decking ok//ok to insulate upper wall areas to finish exterior sheathing//need to add strapping at windows per details on plans// add truss blocking per truss details and plans at strapping required on roof decking//
BLD-Concrete12/5/201912/6/201912/6/2019PPART
DetailsTell Riley
rebar - slab // Shane Phone #: ###-####//need to add transverse bars//WIP// pending specials//
BLD-Energy code compliance11/14/201911/14/201911/14/2019PPART
DetailsTell Riley
Foundation insulation, late PM if possible. Phone #: ###-#### Inspection requested via web by Michael McHargue//ok per plan//will need to add 2' return under slab per drawings//
BLD-Foundation11/8/201911/12/201911/12/2019APASS
DetailsTell Riley
Dane Phone #: ###-####//ok pending specials//
BLD-Footing11/6/201911/7/201911/7/2019PPART
DetailsTell Riley
Dane Phone #: ###-####//ok pending special inspections//