Permit NumberESC16-01512
StatusFinaled
Name DAVE PERKINS
Site Address 12142 W JOPLIN RD
Project NameFire Training Facility
Customer Number 
ePlanReviewNo
Description
Excavation and construction of multi-building fire training center, including grading and uitlity work. SWPPP prepared for CGP and City of Boise ESC requirements. Project includes installation of new drainage swales. Groundwater expected between 3.3' -6.5' below ground surface. Parcel adjacent to Thurman Mill Canal and Thurman Drain. Project expected to start March 2017. BMPs include phasing of project to limit amount of total disturbed area at any one time, perimeter sediment control (silt fence & wattles listed) along Thurman Mill Canal and project frontage along WBTP access road, stabilized construction entrance(s), and concrete washout facilities. Fiber wattle to be installed around the "fill area for grading spoils" west of the main site. ESC site preparation inspection required. Call 608-7070. Note: work include canal crossing for water line utilities. No specific ground water dewatering plan provided in SWPPP
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final5/30/20185/30/20185/30/2018PPASS
DetailsMichael Zawacki
General Inspection5/16/20185/16/20185/16/2018 PASS
DetailsMichael Zawacki
Site nearly complete. Grass is growing on most exposed areas. Job trailer and most construction equipment is gone. Still a few workers finishing up.
General Inspection5/1/20185/1/20185/1/2018PPASS
DetailsMichael Zawacki
Site is mostly complete and undergoing stabalization. No ESC issues.
General Inspection4/17/20184/17/20184/17/2018 PASS
DetailsMichael Zawacki
Area clean. Some work in the Eagle sections.
General Inspection3/29/20184/2/20184/3/2018APASS
DetailsAndy J. Long
Minimal activity. No violations observed in Pamela Baker park section of project.

Rest of adjacent subdivision project is in Eagle. Bankside vegetation of Thurman Mill ditch passing through site has started to grow. No detectable impact on turbidity of water passing through site.

No corrections issued.
General Inspection3/27/20183/27/20183/29/2018 CANC
DetailsAndy J. Long
rescheduled
General Inspection3/12/20183/12/20183/12/2018PFAIL
DetailsAndy J. Long
No trackout, perimeter silt fence and clearing limits next to Thurman Mill are in place. Site has extended westward to have staging area.

Correction action needed at site:
- pick up the significant amount of wind blown trash caught in silt fence and vegatation next to Thurman Mill canal.
- empty or cover dumpster to prevent wind blown trash
- if dry weather continues, fugitve dust control water truck will need to be active if earthwork is occuring. Some dust onsite due moving stockpiles out of staging area.
General Inspection2/22/20182/27/20182/28/2018PPASS
DetailsMichael Zawacki
Most ground disturbance complete. Current construction is all on the existing buildings. Job trailer and central storage has been removed, now is graded road mix. No issues on site.
General Inspection2/20/20182/22/20182/22/2018PCANC
DetailsAndy J. Long
General Inspection2/19/20182/19/20182/20/2018 CANC
DetailsAndy J. Long
rescheduled
General Inspection2/2/20182/2/20182/2/2018 PASS
DetailsMichael Zawacki
Exterior work about complete on 3 of 4 buildings. Workers relocated mortar mixer closer to active building and are in process of cleaning old area. Washout on site for trucks. Majority of area is paved, no trackout leaving site.
General Inspection1/18/20181/18/20181/18/2018 PASS
DetailsMichael Zawacki
Some mud in site, nothing leaving. No trackout or loose trash. Site is well maintained, most workers parking on paved area.
General Inspection1/3/20181/3/20181/3/2018 PASS
DetailsMichael Zawacki
WIP. Washouts in use, someone was cleaning them during inspection. Site kept clean and no issues observed during inspection.
General Inspection12/19/201712/19/201712/19/2017 PASS
DetailsMichael Zawacki
2 of the Eco-Pans are full and need to be removed, another washout on site is ok. Site clean and free from trash.
General Inspection12/4/201712/4/201712/4/2017 PASS
DetailsMichael Zawacki
No trackout leaving site. Stockpile has been treated with tackifier. Eco pans on site and in use and maintained. Majority of work is buildings and ground disturbing activities are no toccuring.
General Inspection11/15/201711/17/201711/17/2017APASS
DetailsMichael Zawacki
Site clean, crew was cleaning up loose trash when I arrived. Perimeter controls in place along canals, goats being used for over growth on canal bank. Multiple washouts, no trackout.
General Inspection11/10/201711/10/201711/15/2017 CANC
DetailsAndy J. Long
rescheduled
General Inspection10/26/201710/26/201710/27/2017 PART
DetailsMichael Zawacki
Inspected 10/23/17.
Area clean and well maintained. No issues.
General Inspection10/11/201710/11/201710/13/2017 CANC
DetailsAndy J. Long
General Inspection9/22/20179/26/201710/4/2017APASS
DetailsAndy J. Long
General Inspection9/20/20179/20/20179/22/2017 CANC
DetailsAndy J. Long
General Inspection8/31/20179/5/20179/13/2017ACANC
DetailsAndy J. Long
General Inspection8/31/20178/31/20178/31/2017 CANC
DetailsAndy J. Long
General Inspection8/14/20178/16/20178/18/2017PCANC
DetailsAndy J. Long
General Inspection8/8/20178/10/20178/14/2017PCANC
DetailsAndy J. Long
General Inspection8/4/20178/7/20178/8/2017PCANC
DetailsAndy J. Long
General Inspection7/28/20178/1/20178/4/2017ACANC
DetailsAndy J. Long
General Inspection7/28/20177/28/20177/28/2017 CANC
DetailsAndy J. Long
rescheduled for 8/1
General Inspection7/12/20177/13/20177/13/2017PPASS
DetailsMelissa Jannusch
WIP. concrete washout in use getting near full. There is an addition concrete washout with secondary containment if the first gets fulls. The silt fence along the creek is in good condition. The SCE is in good condition. There is no trackout. The trash is contained. No wind blown trash. A water truck is on site. No dust observed during the inspection.
General Inspection7/12/20177/12/20177/12/2017 CANC
DetailsAndy J. Long
General Inspection5/24/20175/24/20175/24/2017PPASS
DetailsMelissa Jannusch
Work has started. Met with RP on site. Looked a SWPPP plan and talked about BMP plans. Public works is also inspecting.