General Inspection | 7/22/2020 | 7/22/2020 | 7/22/2020 | | CANC |
Michael Zawacki
|
|
|
|
DOC - Permit Finaled | 7/22/2020 | 7/22/2020 | 7/22/2020 | P | PASS |
Michael Zawacki
|
|
|
|
General Inspection | 7/7/2020 | 7/7/2020 | 7/7/2020 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 6/22/2020 | 6/22/2020 | 6/22/2020 | | PASS |
Michael Zawacki
|
|
|
Has been landscaped, still has bond.
|
General Inspection | 6/5/2020 | 6/5/2020 | 6/5/2020 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 5/21/2020 | 5/21/2020 | 5/21/2020 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 5/6/2020 | 5/6/2020 | 5/6/2020 | | PASS |
Michael Zawacki
|
|
|
Exterior work completed, still needs landscaping.
|
General Inspection | 4/21/2020 | 4/21/2020 | 4/21/2020 | | PASS |
Michael Zawacki
|
|
|
Stairs are now completed, no outside work. Lot still needs to be landscaped.
|
General Inspection | 4/6/2020 | 4/6/2020 | 4/6/2020 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 3/20/2020 | 3/20/2020 | 3/20/2020 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 3/5/2020 | 3/5/2020 | 3/5/2020 | | PASS |
Michael Zawacki
|
|
|
Site still needs landscaping. Exterior work and stairs look like they have been completed.
|
General Inspection | 2/19/2020 | 2/19/2020 | 2/19/2020 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 2/4/2020 | 2/4/2020 | 2/6/2020 | | PASS |
Michael Zawacki
|
|
|
Work has resumed. No runoff issues, site clean.
|
General Inspection | 1/20/2020 | 1/20/2020 | 1/21/2020 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 1/3/2020 | 1/3/2020 | 1/3/2020 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 12/19/2019 | 12/19/2019 | 12/23/2019 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 12/4/2019 | 12/4/2019 | 12/4/2019 | | DEFR |
Michael Zawacki
|
|
|
No activity, on hold due to BLD
|
General Inspection | 11/19/2019 | 11/19/2019 | 11/19/2019 | | PASS |
Michael Zawacki
|
|
|
No new activity
|
General Inspection | 11/4/2019 | 11/4/2019 | 11/4/2019 | | PASS |
Michael Zawacki
|
|
|
No new activity on home. Fence has been built around backyard. Access road to back yard from sherman. Neighbors said people are living at house, issues with building permit never resolved.
|
General Inspection | 10/18/2019 | 10/18/2019 | 10/18/2019 | | DONE |
Michael Zawacki
|
|
|
No new activity, BLD issue not resolved.
|
General Inspection | 10/3/2019 | 10/3/2019 | 10/3/2019 | | PART |
Michael Zawacki
|
|
|
No new activity, waiting on resolution of BLD. New road to backyard from Sherman, no stabalization at site.
|
General Inspection | 9/17/2019 | 9/17/2019 | 9/17/2019 | | PASS |
Michael Zawacki
|
|
|
No new activity. Trash on driveway.
|
General Inspection | 8/30/2019 | 8/30/2019 | 8/30/2019 | | PASS |
Michael Zawacki
|
|
|
Site is idle
|
General Inspection | 8/15/2019 | 8/15/2019 | 8/19/2019 | | PASS |
Andy J. Long
|
|
|
No ESC corrections requested.
|
General Inspection | 7/31/2019 | 7/31/2019 | 8/1/2019 | | PASS |
Michael Zawacki
|
|
|
Forms for concrete stillinstalled out front, no new activity. Moving truck in front, looks like someone moving stuff in.
|
General Inspection | 7/16/2019 | 7/16/2019 | 7/16/2019 | P | PASS |
Michael Zawacki
|
|
|
Forms set for new concrete stairs, did not see washout. Trash is making it close to street.
|
General Inspection | 7/3/2019 | 7/3/2019 | 7/3/2019 | | PART |
Michael Zawacki
|
|
|
Lots of trash around home. Box needed or should be hauled off.
|
General Inspection | 6/18/2019 | 6/18/2019 | 6/18/2019 | | PASS |
Michael Zawacki
|
|
|
Gravel pad laid out for driveway, not poured. Area is clean.
|
General Inspection | 5/30/2019 | 5/30/2019 | 5/30/2019 | P | PASS |
Michael Zawacki
|
|
|
Gutters have temporary ADS pipe going to rip rap. Gator guard along lower perimeter of home, seems to be containing dirt. No issues at time of inspection.
|
General Inspection | 5/20/2019 | 5/20/2019 | 5/23/2019 | P | PEND |
Andy J. Long
|
|
|
check up on site for corrections
Temporary gutter installed. No new issues. WIP.
|
Complaint Inspection | 5/17/2019 | 5/17/2019 | 5/20/2019 | P | FAIL |
Andy J. Long
|
|
|
Complaint regarding muddy water flowing offsite to adjacent lots.
No downslope perimeter sediment barrier installed, pile of uncontained trash, evidence of a washout dumped into a stockpile.
Correction requests: - install temporary gutter and direct water to the rocky swale in the backyard. - install perimeter wattle along the bottom of the site ( this was completed Friday during first inspection) - pick up all loose trash - construct or provide new washout containment.
|
General Inspection | 5/15/2019 | 5/15/2019 | 5/16/2019 | | PASS |
Andy J. Long
|
|
|
|
General Inspection | 4/30/2019 | 4/30/2019 | 4/30/2019 | | PASS |
Michael Zawacki
|
|
|
No workers on site. All building material on lot, trash box on lolt. No trackout or dirt on sidewalk.
|
Tracking Control | 4/10/2019 | 4/10/2019 | 4/11/2019 | P | PASS |
Michael Zawacki
|
|
|
Street and sidewalk swept. There is a white dodge van parked in mud again today.
|
Tracking Control | 4/9/2019 | 4/9/2019 | 4/9/2019 | P | FAIL |
Michael Zawacki
|
|
|
Mud tracked from lot across sidewalk and up cul de sac. Message sent to RP with lighthouse homes.
|
BMP Violation | 3/29/2019 | 4/2/2019 | 4/2/2019 | A | PASS |
Andy J. Long
|
|
|
Gutter was swept. Installed DI sediment protection. Crew onsite picking up trash. No new corrections.
|
General Inspection | 3/29/2019 | 3/29/2019 | 3/29/2019 | P | FAIL |
Andy J. Long
|
|
|
Corrections neeeded: - sweep gutter and remove accumulated material in front of storm drain and parked trailer - sweep sidewalk - install gutter check bags above site to trap dirt from uphill. - install sediment protection on storm drain in front of home.
Follow up scheduled
|
General Inspection | 1/30/2019 | 2/1/2019 | 2/7/2019 | A | CANC |
Andy J. Long
|
|
|
|
General Inspection | 1/24/2019 | 1/29/2019 | 1/30/2019 | P | PEND |
Andy J. Long
|
|
|
no changes at site. Corrections needed, follow up scheduled.
|
General Inspection | 1/24/2019 | 1/24/2019 | 1/24/2019 | P | FAIL |
Andy J. Long
|
|
|
Corrections needed:
- provide stabilized access to home from the road to prevent boot and vehicular trackout. - install trash container/trailer/dumpster
|
General Inspection | 1/11/2019 | 1/11/2019 | 1/11/2019 | P | FAIL |
Michael Zawacki
|
|
|
Lots of dirt on road and sidewalk. No permit displayed. Wattle along front perimeter is destroyed.
|
Tracking Control | 1/4/2019 | 1/7/2019 | 1/7/2019 | P | PASS |
Michael Zawacki
|
|
|
Trackout has all been cleaned. Currently trusses are being stored on sidewalk.
|
Tracking Control | 1/2/2019 | 1/3/2019 | 1/4/2019 | P | PEND |
Andy J. Long
|
|
|
|
General Inspection | 12/27/2018 | 12/27/2018 | 12/27/2018 | P | PEND |
Michael Zawacki
|
|
|
Trackout leading down to Sherman. Everything above lot is clean. Needs to be cleaned after work.
|