Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberESC16-00935
StatusIssued
Name CHRISTIE ROTH
Site Address 124 W SKYLARK DR
Project NameNew SFH
Customer Number 
ePlanReviewNo
Description
Permit for the construction of a new 4,125 sq. ft., two story with a basement (first story 1,906 sq. ft., second story 1,237 sq. ft., basement level 982 sq. ft.) single family dwelling with 3 bedrooms, 3.5 bathrooms, approximately *** sq. ft. of covered patio/porch and a *** sq. ft. attached garage
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection8/3/20208/3/20208/3/2020 PASS
DetailsMichael Zawacki
General Inspection7/17/20207/17/20207/17/2020 PASS
DetailsMichael Zawacki
No new activity.
General Inspection7/2/20207/2/20207/2/2020 CANC
DetailsAndy J. Long
General Inspection6/17/20206/17/20206/17/2020 PASS
DetailsMichael Zawacki
Storm drain system working, no issues.
General Inspection5/27/20206/2/20206/3/2020PPART
DetailsMichael Zawacki
Silt fence has been removed, wood post and a t-post still installed.
Heard from source that drainage is flowing wrong way and onto hillside.
General Inspection5/27/20205/27/20205/27/2020 CANC
DetailsAndy J. Long
General Inspection5/12/20205/12/20205/19/2020 FAIL
DetailsAndy J. Long
No runoff or erosion issues observed.

Request to remove silt fence below fence has not been completed.

Notified Roth Homes to remove fence ASAP so permit may be finaled
General Inspection4/10/20204/10/20204/13/2020 CANC
DetailsAndy J. Long
General Inspection3/26/20203/26/20203/26/2020 PART
DetailsMichael Zawacki
Rill filled and wattles placed.
Silt fence still not removed.
General Inspection3/11/20203/11/20203/17/2020 CANC
DetailsAndy J. Long
General Inspection2/25/20202/25/20202/25/2020 FAIL
DetailsMichael Zawacki
Hillside not repaired, still rills and no new watlle.
Old silt fence still behind wood fence.
General Inspection2/10/20202/10/20202/12/2020 PEND
DetailsAndy J. Long
No significant changes. Did not check to see if silt fence had been removed. No new erosion issues observed. Bentonite clay is plugging hole in slope. Will follow up
General Inspection1/24/20201/24/20201/31/2020 CANC
DetailsAndy J. Long
Conference1/7/20201/8/20201/8/2020PPASS
DetailsAndy J. Long
2 PM

Meeting with new project manager.

Bentonite clay has been put inside the eroded hole on the slope to fill it up. The clay will expand and harden.

Other depressions will be filled with dirt to make a solid surface and then slope interupting wattles will be placed above and below the area.

Request to remove the above ground silt fence behind the home's fence. It is no longer needed and started to fall apart.

No other issues at site. Brett with Roth will notify ESC division when work is complete.
Conference1/7/20201/9/20201/8/2020PCANC
DetailsAndy J. Long
Conference12/24/20191/6/20201/7/2020APEND
DetailsAndy J. Long
Cleve no longer with Roth Homes, retired

Stated Brett R is new contact 2089140814.

Notified listed RP Christie to set up conference to address corrections on damaged slope below home.
General Inspection12/19/201912/19/201912/24/2019 FAIL
DetailsAndy J. Long
Need to repair slope erosion controls to the east of home where erosion occured due to flood event.

Follow up conference scheduled for after holidays to get with RP
General Inspection12/4/201912/4/201912/4/2019 PART
DetailsMichael Zawacki
Rills from blowout never fixed. All new driveway drainage goes into gutter.
General Inspection11/19/201911/19/201911/19/2019 PASS
DetailsMichael Zawacki
No new activity
General Inspection11/4/201911/4/201911/4/2019 PASS
DetailsMichael Zawacki
Repairs to drive completed. No issues at site.
General Inspection10/18/201910/18/201910/18/2019 PASS
DetailsMichael Zawacki
Driveway repaired. Still some slurry on hillside.
General Inspection10/3/201910/3/201910/3/2019 PASS
DetailsMichael Zawacki
Driveway has been repaired. No issues on site.
General Inspection9/18/20199/18/20199/19/2019 PASS
DetailsMichael Zawacki
Driveway has been repaired. Mess on hillside below has been cleaned up. Hillside has some rills from blowout and will need some repairs.
General Inspection9/3/20199/3/20199/3/2019 PASS
DetailsMichael Zawacki
Driveway work has begun. First pour and heaters installed, still needs second pour.
Washout on lot up the road,
Conference8/19/20198/19/20198/19/2019PCANC
DetailsAndy J. Long
General Inspection8/13/20198/13/20198/13/2019PPASS
DetailsMichael Zawacki
Driveway repair hasn't begun, materials have been removed from road.
General Inspection7/30/20197/30/20197/31/2019PPEND
DetailsAndy J. Long
Storm drain sumps in road way and for the house drainage system have been hydro-vac'd.

Need to get geotechnical report on slope that was damaged during the water line break in early July.
General Inspection7/24/20197/25/20197/26/2019ADONE
DetailsMichael Zawacki
Looks like drins were cleaned. Did not see anymore white slurry.
General Inspection7/23/20197/23/20197/23/2019 PEND
DetailsMichael Zawacki
Driveway has been cut out and being evaluated by soils engineer. Some saw cutting slurry has gone down drain and bubbled up below, some also has gone out drain into hillside. Talked with RP and will see what ACHD wants done and if they need to vac out drains. Broken concrete is currently in road.
BMP Violation7/23/20197/23/20197/23/2019PDONE
DetailsAndy J. Long
Reinspection fee and parcel hold. Must be paid and issue on site addressed prior to removal of parcel hold.
General Inspection7/8/20197/8/20197/9/2019PCANC
DetailsAndy J. Long
Complaint Inspection7/5/20197/8/20197/8/2019APEND
DetailsAndy J. Long
report of broken water line and flooding.

Met with downhill homeowner and GC regarding damage from broken water line.

GC will have soils engineer assess slope stability where water has eroded some of the hillside. Excavator was onsite reparing damaged driveway/easement.

Notified PW HIllside. Case pending. Will wait for geotechnical report information for further corrections.
General Inspection6/21/20196/21/20196/24/2019 CANC
DetailsAndy J. Long
General Inspection6/6/20196/6/20196/10/2019 PASS
DetailsMichael Zawacki
Stee side hill has been landscaped, back yard seeded. Home looks completed, no ESC issues.
General Inspection5/22/20195/22/20195/22/2019 PASS
DetailsMichael Zawacki
Washout has been cleaned and new washout installed.
Gutters on home have been hooked up into system. No rills or runoff from site. Lower drainage is working, will be filled with drainage rock for appearances.
BMP Violation5/7/20195/7/20195/7/2019PFAIL
DetailsMichael Zawacki
Washout still not cleaned, was told it would be done by end of week on 4-24.
Parcel hold and reinspection fee issued.
BMP Violation4/26/20194/29/20194/29/2019APEND
DetailsAndy J. Long
Follow up from failed inspection

Notified Cleve with Roth that adjacent site where washout from driveway placement was dumped must be cleaned up and a new washout installed.
General Inspection4/26/20194/26/20194/26/2019PFAIL
DetailsMichael Zawacki
Dumped wshout not cleaned.
General Inspection4/26/20194/26/20194/26/2019 CANC
DetailsMichael Zawacki
Entry error
General Inspection4/11/20194/11/20194/11/2019 PASS
DetailsAndy J. Long
General Inspection3/27/20193/27/20193/27/2019 PASS
DetailsMichael Zawacki
Inspected 3/26. Spoke with Roth Homes foreman. All material off of road, said they had some mud but cleaned it all.
General Inspection3/12/20193/12/20193/12/2019 PASS
DetailsMichael Zawacki
Inspected 3-11. No ESC issues, no activity at time of inspection.
General Inspection2/25/20192/25/20192/27/2019 PASS
DetailsMichael Zawacki
No workers on site, no materials on road. Did not walk hillside due to rain and mud.
General Inspection2/8/20192/8/20192/8/2019 PART
DetailsMichael Zawacki
Swale underneath has been cleaned. Some isulation and other trash blown down hillside and to fence, needs clean up.
BMP Violation1/24/20191/24/20191/24/2019PPASS
DetailsAndy J. Long
General Inspection1/18/20191/18/20191/24/2019 CANC
DetailsAndy J. Long
General Inspection1/24/20191/24/20191/24/2019PCANC
DetailsAndy J. Long
General Inspection1/3/20191/3/20191/7/2019 PASS
DetailsMichael Zawacki
Trash and materials clened from front of home. No ESC issues.
General Inspection12/12/201812/19/201812/19/2018PFAIL
DetailsMichael Zawacki
Pile of trash out front hasn't been removed.
General Inspection12/12/201812/12/201812/12/2018PPART
DetailsAndy J. Long
No muddy runoff. ESC BMPs installed.

correction needed:
pick up uncontained trash and debris pile in front of home. Provide a trash container.

Verbal correction to Roth Homes Kevin. Follow up next week.
BMP Violation11/21/201811/28/201811/29/2018PPEND
DetailsAndy J. Long
Some corrections have been completed:

- Drainage swale has been cleaned out and re-lined as requested.
- Trash on hillside by home has been picked up
- wattles on the west side of home have been replaced and new ones installed.
- wattle placed below swale as requested (needs some re-installation to trenched and along contour)

Corrections remaining:
- clean up trash pile in front of home
- fix wattles below swale
- install storm drain grate in correct direction

Follow up meeting to be scheduled with Kevin from Roth Homes.
General Inspection11/15/201811/20/201811/21/2018PFAIL
DetailsAndy J. Long
No corrective actions on swale. Loose trash in front of home.

Kevin with Roth Homes onsite. Requested additional wattle installation below swale until further maintenance is completed.

Switch sediment bag in lowest storm drain to upper storm drain on Skylark to prevent overflow and treat initial runoff.
General Inspection11/15/201811/15/201811/15/2018 PEND
DetailsAndy J. Long
no inspection. Spoke with Cleve regarding the storm drain swale repair. WIP to make it operational. Follow up next week
General Inspection10/31/201810/31/201811/8/2018 FAIL
DetailsAndy J. Long
Correction notice to clean out and maintain the drainage swale below the home. Risk of overflow and erosion. Lining has been ripped out and trough now filled with dirt.

Verbal correction to Roth Homes.
General Inspection10/16/201810/16/201810/16/2018 FAIL
DetailsMichael Zawacki
Washout in front was never cleaned. Drain below home looks full of sand. Hillside work on top pushed some fill over wattles and disturbed vegetation.
General Inspection10/1/201810/1/201810/2/2018 FAIL
DetailsMichael Zawacki
Some type of washout next to curb, dumped in dirt, no containment.
General Inspection9/14/20189/14/20189/19/2018 CANC
DetailsAndy J. Long
General Inspection8/30/20188/30/20188/30/2018 PASS
DetailsMichael Zawacki
Inlets at end of road are all protected. Pile of gravel off of road. Demo work has started on old remaining home.
BMP Violation8/15/20188/15/20188/15/2018APART
DetailsAndy J. Long
Some correction completed:

- stockpile moved out of gutter
- upper DI bag emptied and re-installed
- lined swale has been cleaned out with dirt and trash removed as requested.


Not completed:
- spill absorbent and planks obstructing lower drains at end of culdesac.
BMP Violation8/14/20188/14/20188/15/2018PPEND
DetailsAndy J. Long
compliance deadline extended to 8/15 AM
BMP Violation8/9/20188/9/20188/13/2018PPEND
DetailsAndy J. Long
illegal stockpile on top of a storm drain
BMP Violation8/13/20188/13/20188/13/2018PFAIL
DetailsAndy J. Long
illegal stockpile on top of a storm drain reported Thursday Aug 9th has still not be cleaned or relocated as requested to RP Cleve via text message.

No clean up of road mix material dumped around storm drains. DI bags full and unmaintained. Spill absorbent/kitty litter left in gutter.

Lined swale is full of dirt, weeds and some trash. Grass on slopes is not watered and probably dying. May require additional revegetation this fall.
General Inspection7/30/20187/30/20187/30/2018 PART
DetailsMichael Zawacki
Load of pitrun has been dumped halfway on road, on top of protected storm drain. Sand bag around lower drain is starting to fail and lose sand, inlet has witches hat. Hillside is stable.
General Inspection7/13/20187/13/20187/13/2018 CANC
DetailsMichael Zawacki
General Inspection6/28/20186/28/20186/28/2018 PASS
DetailsMichael Zawacki
Hillsides are stable. New trenches for power, stockpile on site, very close to being in road. Unable to check drainage below home, trench blocked access on one side, scaffolding on other. Trash is contained at both sites, right of way not being used for storage. No ESC issues at either site.
General Inspection6/13/20186/13/20186/13/2018 PASS
DetailsMichael Zawacki
Hillsides are covered with growth , no loose dirt or fugitive dust. Trash is contained. ACHD has paved the road and installed/repaired curb gutters. Inlet protection now in all lower DIs.
General Inspection5/29/20185/29/20185/29/2018PPART
DetailsAndy J. Long
No sediment runoff observed or reported. Slopes and drainage system have not been overwhelmed by recent storms.

Correction request:
- clean up accumulated dirt in lined swale below home
- remove unused wattles around site
- continue to work with neighbor on tree replacement

WIP on interior framing.
Conference5/9/20185/16/20185/18/2018PCANC
DetailsAndy J. Long
General Inspection5/3/20185/4/20185/9/2018APEND
DetailsAndy J. Long
No new violations observed. Disturbed slopes are in process of revegetation. No significant bare areas or erosion rills observed. Final landscaping has not been completed. Foundation and frame complete, WIP on interior.
None of the corrections requested in March appear have been completed other than making the lined drain flow towards the outlet pipe when water collects in it.

Corrections needed:
- remove unused wattle from bottom corner of lot
- install properly trenched in wattle between the drain and bottom corner.
- work with neighbor to replace damaged tree and gravel in driveway as discussed.

General Inspection5/2/20185/2/20185/3/2018 CANC
DetailsAndy J. Long
rescheduled
General Inspection4/17/20184/17/20184/18/2018 PASS
DetailsMichael Zawacki
Site contained, hillside grasses coming in. No ESC issues.
General Inspection4/2/20184/2/20184/2/2018 PASS
DetailsMichael Zawacki
Grass is growing well on hillsides. Nothing is being stored on road. No issues with dirt or runoff.
Conference3/14/20183/16/20183/19/2018PDONE
DetailsAndy J. Long
130 PM

Lined drainage trench has been cleaned out and relaid to improve flow to drain and prevent overtopping. Front of site is clean, no trackout and trash container has been emptied.

Corrections requested:
- landscaper foreman/crew to discuss tree replacement and revegetation with downhill neighbor
- install wattle U-hooks/check dams along bottom fence line to slow any water flowing along the fence liner.
- clean up old/unused wattles at discharge point at corner of fence.
- install section of wattle on slope between the drainage trench and bottom corner of lot.
General Inspection3/15/20183/15/20183/15/2018PPEND
DetailsAndy J. Long
Site inspection conducted to check up and initiate repair of lined drainage swale. As of 11 15 AM no work had been conducted. Called Roth Homes Cleve, onsite crew member Dave started to work on cleaning out swale, directing water to drain and to vegetated area, pull up lining and remove dirt/mud causing obstruction of flow to drain. Follow up scheduled for tomorrow.
Complaint Inspection3/5/20183/6/20183/8/2018APEND
DetailsAndy J. Long
Skylark street is in good condtion, no trackout, trash contained, storm drains have sediment protection in designated inlets.



Disturbed slopes have jute matting and seeding in place with slope interupting wattles. Wattles are not overlapping , will continue to monitor tp see of water is channeling there.

Drainage swale may need re-installation, water is ponding in low spot in trench instead of going drain.

Damage on lot below home from previous runoff events discussed with neighbor.
- dead tree and damaged vegetation in area where mud ran down hill. Homeowner wants tree replacement and reseeding.
- mud/dirt deposited in driveway and between garage and slope has changed grade and is creating ponding and mud. Regrading and import gravel requested.

RP has been notified to reach out to neighbor and check into swale/drainage channel below home.
Complaint Inspection3/1/20183/1/20183/5/2018PCANC
DetailsAndy J. Long
General Inspection2/21/20182/21/20182/21/2018 PASS
DetailsMichael Zawacki
Hillside BMPs still in place. No runoff onto road. Trash and lumber is being put into trash box. Some lumber is being stored on road in cul-de-sac.
General Inspection2/6/20182/6/20182/6/2018 PASS
DetailsMichael Zawacki
Work has begun on framing. Area is fenced off and no materials stored on road.
Tracking Control1/22/20181/22/20181/24/2018PPASS
DetailsMichael Zawacki
Check for clean right of way.
Everything has been cleaned off road.
Complaint Inspection1/22/20181/22/20181/22/2018AFAIL
DetailsMichael Zawacki
email complaint about poor housekeeping
Left message with Christie Roth to have right of way cleaned by 1/24. Sheduled follow up inspection.
General Inspection1/19/20181/19/20181/19/2018 PART
DetailsMichael Zawacki
Hillside BMPs are holding up, no issues with hills. Sonme dirt on road and in gutters. Is coming from home above new properties.
General Inspection1/4/20181/4/20181/4/2018PPART
DetailsMichael Zawacki
Hillside has been protected with wattle, jute, and tackifier. Has hel up fine to snow melt. Outpak washout is full, there has been washout onto the ground. Trench exposed for water, some dirt is on road.
General Inspection12/22/201712/22/201712/22/2017 CANC
DetailsAndy J. Long
General Inspection12/7/201712/7/201712/7/2017 PEND
DetailsMichael Zawacki
Area has been stabalized. Pile of gravel in road, will need to monitor to see if it is soon removed.
General Inspection11/22/201711/22/201711/22/2017PPASS
DetailsMichael Zawacki
Trackout cleaned. Hillside now has jute, wattle, and has been hydro seeded.
General Inspection11/15/201711/15/201711/15/2017APEND
DetailsAndy J. Long
Trash contained, street has been recently swept. Some inlets have sediement filter bags, others do not in order to prevent and overflow and water running down slope instead of in pipe.

Still no erosion controls (hydromulch with tacifier, slope interupting wattles) on the slopes. Slopes have raked flat and are ready for installation.

RP Cleve says he is expecting the work to be done this week or next.
General Inspection11/9/201711/9/201711/9/2017PFAIL
DetailsMichael Zawacki
Excessive trackout on road. No protection on steep slopes.
Site Preparation11/2/201711/2/201711/2/2017ACANC
DetailsAndy J. Long
Random Inspection10/30/201710/30/201710/30/2017PPASS
DetailsMichael Zawacki
No dirt leaving site. Hillsides are expose and unprotected.
BMP Violation10/16/201710/16/201710/19/2017PPEND
DetailsAndy J. Long
crew has cleaned up uncontained washout per RP Cleve. Road also being swept on 10/18. Will follow up at site and post new ESC permits.

Earthwork to occur this week and next and schedule is set to have erosion control blankets installed within 2-3 weeks.
General Inspection10/4/201710/4/201710/11/2017 FAIL
DetailsMichael Zawacki
No permit displayed or ESCP/SWPPP book. Entire hillside is bare and loose, no BMPs to prevent water from racing downhill. Would install swales to divert water or wattle and blanket to protect dirt. Would like to see tackifier or hydro seed before winter weather. One of four DIs is not protected. Is next to 140 Skylark which shares responsibility for hillside.
General Inspection9/19/20179/19/20179/22/2017 CANC
DetailsAndy J. Long
General Inspection9/4/20179/4/20179/5/2017 CANC
DetailsAndy J. Long
BMP Violation8/18/20178/18/20178/18/2017PFAIL
DetailsAndy J. Long
Disturbed slopes need temporary stabilization due to slow progress of project and approaching wet season.

Maintenance needed on sediment control wattle at bottom of lot.

Need full size dumpster for workers on site.

Site conference scheduled for next week to discuss corrections.
General Inspection8/16/20178/16/20178/18/2017 CANC
DetailsAndy J. Long
General Inspection8/1/20178/1/20178/7/2017 CANC
DetailsAndy J. Long
General Inspection7/10/20177/17/20177/17/2017ACANC
DetailsMelissa Jannusch
BMP Violation7/7/20177/14/20177/14/2017APASS
DetailsMelissa Jannusch
Trash, trackout, and concrete washout have been cleaned up. Project back in compliance status.
General Inspection7/10/20177/10/20177/10/2017PPART
DetailsMelissa Jannusch
Concrete slurry has been cleaned up and trackout swept. Trash is still full.
General Inspection7/10/20177/10/20177/10/2017PPART
DetailsMelissa Jannusch
Concrete slurry has been cleaned up and trackout swept. Trash is still full.
General Inspection7/5/20177/5/20177/7/2017 FAIL
DetailsMelissa Jannusch
WIP on road, curb, and gutters. Staging lane is clean, trash is contained. No ESC corrections observed.
Concrete slurry flowing down side of hill to vegetation. Silt fence ok. No curb installed under fence. Trackout. Wattles not staked. Overflowing trash. No dust problems at time of inspection.
Corrections requested:
Clean up concrete washout that has spilled downhill. Install concrete washout to properly contain concrete. Communicate use to subcontractors
Clean up overflowing trash
Sweep up trackout
Restake wattles
Left voice message and text message with GC Cleve requesting corrections
Follow up next week
General Inspection6/20/20176/20/20176/20/2017PPASS
DetailsAndy J. Long
Skylark Street is free of trackout. Trash and materials are contained. No dischages or spilled materials

Corrective actions from previous inspection have been completed. No sediment runoff or mud has been reported. Corrections assisted in storm received last week.

- backfill silt fence section
- install J-hooks on wattles along property fence
- stake down all wattles strips not currently staked

General Inspection6/6/20176/9/20176/9/2017APASS
DetailsAndy J. Long
follow up inspection

Requested corrections have been completed:
- trash container removed.
- street sweeping on Skylark
- silt fence section has been repaired. Still needs backfill to trench in
- upper stockpile has perimeter protection and has been removed off of curbing and adjacent driveway
- excavated mud removed from neighbors has been cleared.



Site is now back in ESC compliance.
Further adjustments:
- backfill silt fence section
- install J-hooks on wattles along
- stake down all wattles strips not currently staked
General Inspection6/6/20176/6/20176/6/2017PFAIL
DetailsAndy J. Long
Correction requests from previous inspection have not been completed. The corrections below are specific to the Skylark lower lot.

Corrections remaining:

1. Repair or re-install section of silt fence below the wooden fence that is damaged.
2. Provide a clearly marked designated concrete washout pit.
3. Need to empty full trash container.
4. Sweep up loose dirt in culdesac in front of site.
5. Remove mud pile left in downhill neighbors driveway.

See also ESC16-00936 for inspection requests.

This is the 2nd correction request. If corrections are not complete will need to escalate with fines and/or SWO until all corrections can be made.

Note: corrections completed include some street street sweeping and removing an inlet bag to prevent accidental overflow.
General Inspection6/2/20176/2/20176/6/2017 CANC
DetailsAndy J. Long
General Inspection6/6/20176/6/20176/6/2017PFAIL
DetailsAndy J. Long
Inspections notes from 6/1 (entered under 140 Skylark , see ESC16-00936



Reviewed damage and uncleaned areas around downhill neighbor's detached garage. There is evidence of damage to the slope area direcctly behind garage.

Section of silt fence is below the wooden fence needs re-installation. Low point of perimeter wattle along fence needs to be corrected to not channel water to this area.

Corrections needed:
- sweep gutter in front of projects
- empty over full trash containment
- provide concrete washout pit - currently just spraying down the slope
- set schedule for disturbed slope stabilization
- install wattle along stockpile in front of upper project as previously requested and agreed to.
General Inspection5/18/20175/18/20175/18/2017 PEND
DetailsAndy J. Long
General Inspection4/19/20175/3/20175/3/2017APASS
DetailsMelissa Jannusch
Excavation WIP. Sediment fence is okay.
General Inspection4/13/20174/19/20174/19/2017APEND
DetailsMelissa Jannusch
Fence is still not installed. No other issues.
General Inspection4/13/20174/13/20174/13/2017PPEND
DetailsMelissa Jannusch
Excavator in use. Fence still not complete.
Site Preparation4/11/20174/14/20174/13/2017ACANC
DetailsMelissa Jannusch
General Inspection4/7/20174/11/20174/11/2017APEND
DetailsMelissa Jannusch
WIP during time of inspection. The fence is still not completed. Silt fence is leaning over.
General Inspection4/5/20174/7/20174/7/2017APEND
DetailsMelissa Jannusch
No new developments. Fence still not finished.
Complaint Inspection3/31/20174/5/20174/5/2017APASS
DetailsMelissa Jannusch
No new issues. Sediment has been removed from the silt fence and the silt fence has been set upright and re-staked. Fence is not complete yet. Wattles are in place. Okay.
Complaint Inspection3/30/20173/31/20173/31/2017APEND
DetailsMelissa Jannusch
Wattles have been replaced on roadway. Silt fence still has sediment on top of it. Nothing else new.
Complaint Inspection3/30/20173/30/20173/30/2017PFAIL
DetailsMelissa Jannusch
Met onsite with RP. The slope did not fail. The silt fence at the bottom of the site failed and overflowed water and dirt into the downhill property. The portion of the silt fence that was removed to allow for the building of the fence was not where the overflow occurred.
RP and crew are currently
1) Replacing wattles that were located in the road way to slow down overland flows
2) Dig a channel to send water into the vegetated perimeter and away from homeowner’s property
3) Removed sediment from behind remaining silt fence
RP has spoken with the homeowner and has committed to cleaning the sediment out of his garage area.
They hope to finish the fence in the next few days.
General Inspection3/29/20173/29/20173/29/2017PPEND
DetailsMelissa Jannusch
A portion of the silt fence at the bottom of the site has been removed. Left message with RP requesting maintenance on silt fence.
General Inspection3/16/20173/16/20173/20/2017 PASS
DetailsMelissa Jannusch
WIP. BMPs okay no maintenance needed. No corrections requested. Met with RP on site and discussed planed construction timeline.
General Inspection3/1/20173/1/20173/1/2017 PASS
DetailsMelissa Jannusch
Silt fence in good condition. No run off to lot downhill of site. Wattles are placed on roadway to direct and slow water. Addition gravel of construction entrance is on site. No trackout. Sign is posted. No work currently underway, but an excavator is on site. No corrections requested
General Inspection2/10/20172/14/20172/14/2017APASS
DetailsMelissa Jannusch
Sediment has been removed from behind silt fence. Silt fence is in good condition. Wattles have been placed on the slope to slow the water. A tarp has been placed over some of the excavated area. Has a wattle under the tarp.
okay
General Inspection2/7/20172/8/20172/10/2017PCANC
DetailsAndy J. Long
rescheduled 2/14
Complaint Inspection2/6/20172/6/20172/6/2017APEND
DetailsAndy J. Long
Concern about runoff accumulating at bottom of slope on lot potentially damaging stability of slope below silt fence.

WIP to conduct maintenance on silt fence and wattle at bottom of hill by removing captured mud. RP and excavator to install additional wattles up hill to divert flows offsite to the vegetated perimter.
General Inspection12/1/201612/15/201612/21/2016ACANC
DetailsAndy J. Long
General Inspection11/15/201611/30/201612/1/2016PPASS
DetailsAndy J. Long
WIP on foundation excavation for adjacent hillside lots. Silt fence and security/ debris catchment fence installed below work area.
Site Preparation11/14/201611/15/201611/15/2016PPASS
DetailsAndy J. Long
2:00 PM Cleve Cushing ###-####

First phase of construction is to install permanent heavy duty fencing and stormwater swale at bottom of lot for drainage. Perimeter silt fence has been installed properly per ESC plan.

No DI protection to be installed due to slope of road and catchment area for storm drain. Do not want to overwhelm or clog inlets which could send stormwater over the hillside or onto existing property. RP Cleve to increase gutter and street sweeping frequency.

Approved for construction.
General Inspection4/27/20204/27/2020   
DetailsAndy J. Long